OSHA SearchOSHA records by employer

Roof-Technologies, Inc.: OSHA inspections and violations

Baton Rouge, Louisiana · Roofing Contractors · NAICS 238160

11inspections
15citation items
$23,352current penalties
May 3, 2018last inspection

Roof-Technologies, Inc. has 11 OSHA inspections on record in Louisiana, the first in 1992.

OSHA's last visit started on May 3, 2018 as a planned inspection, in Metairie.

Across those inspections OSHA issued 15 citation items: 8 serious, 2 repeat and 5 other-than-serious.

OSHA proposed $33,792 in penalties. After settlements and reviews the total is $23,352, down 31%.

Most often, OSHA cited 1926.501, fall protection in construction (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Roof-Technologies, Inc. averages $6,467 over 1 cited inspection in that time.

Roof-Technologies, Inc.: OSHA citation items per year, 1992 to 2018
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Roof-Technologies, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343133526 OPENED MAY 3, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jun 4, 2018

7212 Veterans Blvd., Metairie, LA 70003 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Other-than-serious$6,467$6,467May 10, 2018Final

Inspection 339739401 OPENED MAR 20, 2014Closed

Planned · Complete · Safety · 52 employees at the site · Closed Jun 2, 2014

104 Orleans St., Belle Chasse, LA 70037 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$2,975$2,975May 2, 2014Final

Inspection 313029159 OPENED FEB 25, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 25, 2010

6400 Perkins, Baton Rouge, LA 70808 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311526735 OPENED AUG 22, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 14, 2008

6400 St. Claude Ave., New Orleans, LA 70117 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(d)(6)(i) · Fall protection systems
Other-than-serious$750$0Sep 25, 2008Closed

Inspection 307602375 OPENED MAY 16, 2005Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jun 24, 2006

626 N. 4th St., Baton Rouge, LA 70804 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$7,500$3,750May 24, 2005Closed

Inspection 307599183 OPENED JAN 20, 2005Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 24, 2006

9536 Airline Hwy, Baton Rouge, LA 70815 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,000$1,800Feb 8, 2005Closed
Citation 2, item 1
29 CFR 1926.502(f)(2)(i) · Fall protection systems
Other-than-serious$0$0Feb 8, 2005Closed
Citation 2, item 2
29 CFR 1926.502(f)(2)(ii) · Fall protection systems
Other-than-serious$0$0Feb 8, 2005Closed

Inspection 305964298 OPENED FEB 18, 2004Closed

Planned · Partial · Safety · 50 employees at the site · Closed Jun 9, 2004

6400 Perkins, Baton Rouge, LA 70808 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$3,000$2,100Apr 13, 2004Closed

Inspection 305957912 OPENED MAR 3, 2003Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 25, 2003

626 N. 4th St., Baton Rouge, LA 70804 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,500$1,750Apr 30, 2003Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,500$1,750Apr 30, 2003Closed
3 older inspections

Inspection 303077770 OPENED NOV 4, 1999Closed

Planned · Complete · Safety · 13 employees at the site · Closed Nov 24, 1999

1200 Champagne St., Covington, LA 70433 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$700$420Nov 22, 1999Closed
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$700$420Nov 22, 1999Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$700$420Nov 22, 1999Closed

Inspection 123465155 OPENED MAR 25, 1996Closed

Planned · Complete · Safety · 8 employees at the site · Closed May 3, 1996

626 N. 4th St., Baton Rouge, LA 70804 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108770256 OPENED JAN 7, 1992Closed

Planned · Complete · Safety · 17 employees at the site · Closed Apr 15, 1992

626 N. 4th St., Baton Rouge, LA 70804 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Serious$500$250Feb 6, 1992Closed
Citation 1, item 2
29 CFR 1926.500(g)(5) · Scope, application, and definitions applicable to this subpart
Serious$2,500$1,250Feb 6, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.502 · Fall protection systems

OSH Act Section 5 · General Duty Clause

Other roofing contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.