Inspection 343416806 OPENED AUG 23, 2018Closed
620 W. Town Center Blvd. Menards, Champaign, IL 61822 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Roofoptions, LLC 3 times in Illinois since 2012.
The latest one began on Aug 23, 2018 after a complaint, in Champaign.
Those inspections ended with 8 citation items: 6 serious and 2 other-than-serious.
Penalties were first proposed at $23,921 and now stand at $14,880, 38% lower after settlements or reviews.
Fall protection systems comes up most often in these citations: 3 items under 1926.502.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Roofoptions, LLC averages $9,000 (1 cited inspection).
Want to know if OSHA cites Roofoptions, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company620 W. Town Center Blvd. Menards, Champaign, IL 61822 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1801 Pleasant, Dekalb, IL 60115 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Other-than-serious | $9,054 | $0 | Sep 14, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $6,467 | $9,000 | Sep 14, 2018 | Final |
300 N. Randall, Batavia, IL 60510 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(a)(1) · Fire protection |
Serious | $1,600 | $1,120 | Jun 11, 2012 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(4)(i) · Fall protection in construction |
Serious | $2,000 | $1,400 | Jun 11, 2012 | Final |
| Citation 1, item 3a 29 CFR 1926.502(f)(1) · Fall protection systems |
Serious | $2,000 | $1,400 | Jun 11, 2012 | Final |
| Citation 1, item 3b 29 CFR 1926.502(f)(1)(i) · Fall protection systems |
Serious | $0 | $0 | Jun 11, 2012 | Final |
| Citation 1, item 4 29 CFR 1926.502(h)(1)(v) · Fall protection systems |
Serious | $2,800 | $1,960 | Jun 11, 2012 | Final |
| Citation 2, item 1 29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Jun 11, 2012 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.178(l)(6)
(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.150(a)(1)
(a) General requirements. (1) The employer shall be responsible for the development of a fire protection program to be followed throughout all phases of the construction and demolition work, and he shall provide for the firefighting equipment as specified in this subpart. As fire hazards occur, there shall be no delay in providing the necessary equipment.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.