OSHA SearchOSHA records by employer

Ruby's Auto Body Inc.: OSHA inspections and violations

La Junta, Colorado · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

2inspections
9citation items
$8,086current penalties
Feb 13, 2025last inspection

OSHA has inspected Ruby's Auto Body Inc. 2 times in Colorado since 2024.

The latest one began on Feb 13, 2025 on a referral, in La Junta.

Those inspections ended with 9 citation items: 5 serious and 4 other-than-serious.

Penalties were first proposed at $9,221 and now stand at $8,086, 12% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Ruby's Auto Body Inc. averages $4,043 (2 cited inspections).

Ruby's Auto Body Inc.: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Ruby's Auto Body Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348044124 OPENED FEB 13, 2025Closed

Referral · Partial · Health · 11 employees at the site · Closed Aug 27, 2025

213 West 3rd Street, La Junta, CO 81050 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,837$2,837Jul 30, 2025Final
Citation 1, item 1b
29 CFR 1910.134(i)(6) · Respiratory protection
Serious$0$0Jul 30, 2025Final
Citation 1, item 2a
29 CFR 1910.1000(a)(1) · Air contaminants
Serious$3,547$3,547Jul 30, 2025Final
Citation 1, item 2b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jul 30, 2025Final
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Jul 30, 2025Final

Inspection 347866816 OPENED NOV 5, 2024Closed

Planned · Partial · Safety · 11 employees at the site · Closed Mar 14, 2025

213 West 3rd Street, La Junta, CO 81050 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,837$1,702Feb 27, 2025Final
Citation 2, item 1
29 CFR 1910.29(b)(2) · Fall protection systems in general industry
Other-than-serious$0$0Feb 27, 2025Final
Citation 2, item 2
29 CFR 1910.106(d)(5)(i) · Flammable liquids
Other-than-serious$0$0Feb 27, 2025Final
Citation 2, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Feb 27, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(1)

(a) Table Z-1—(1) Substances with limits preceded by “C”—Ceiling Values. An employee's exposure to any substance in Table Z-1, the exposure limit of which is preceded by a “C”, shall at no time exceed the exposure limit given for that substance. If instantaneous monitoring is not feasible, then the ceiling shall be assessed as a 15-minute time weighted average exposure which shall not be exceeded at any time during the working day.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(5)(i)

(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.334 · Using electrical equipment

Other automotive body, paint, and interior repair and maintenance employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.