OSHA SearchOSHA records by employer

Rudeen Development LLC: OSHA inspections and violations

Post Falls, Idaho · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

4inspections
6citation items
$3,161current penalties
Jun 22, 2017last inspection

OSHA has inspected Rudeen Development LLC 4 times in Idaho since 2008.

The latest one began on Jun 22, 2017 as part of a related case, in Post Falls.

Those inspections ended with 6 citation items: 3 serious and 3 other-than-serious.

Penalties were first proposed at $5,872 and now stand at $3,161, 46% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rudeen Development LLC averages $1,811 (1 cited inspection).

Rudeen Development LLC: OSHA citation items per year, 2008 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Rudeen Development LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342426301 OPENED JUN 22, 2017Closed

Unprogrammed related · Partial · Safety · 24 employees at the site · Closed Sep 2, 2017

4148 E 16th Avenue, Post Falls, ID 83854 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,622$1,811Jul 13, 2017Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Jul 13, 2017Final

Inspection 334434537 OPENED MAY 16, 2012Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jul 16, 2012

3901 W. Seltice Way, Post Falls, ID 83854 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,800$900Jun 7, 2012Final
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Jun 7, 2012Final

Inspection 311579007 OPENED OCT 3, 2008Closed

Unprogrammed related · Partial · Safety · 40 employees at the site · Closed Oct 29, 2008

2780 W Mcmillan, Meridian, ID 83642 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311576060 OPENED APR 17, 2008Closed

Unprogrammed related · Partial · Safety · 20 employees at the site · Closed Aug 14, 2008

550 Larkspur St., Sandpoint, ID 83852 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Other-than-serious$450$450Jul 18, 2008Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Jul 18, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other new multifamily housing construction (except for-sale builders) employers in Idaho

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.