OSHA SearchOSHA records by employer

Ryan Scott Development, LLC: OSHA inspections and violations

Milwaukee, Wisconsin · New Housing For-Sale Builders · NAICS 236117

1inspections
7citation items
$4,800current penalties
Sep 11, 2018last inspection

OSHA has inspected Ryan Scott Development, LLC once in Wisconsin.

The inspection began on Sep 11, 2018 as a planned inspection, in Milwaukee.

That inspection ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $9,423 and now stand at $4,800, 49% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ryan Scott Development, LLC averages $4,800 (1 cited inspection).

Ryan Scott Development, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

232employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Ryan Scott Development, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343457727 OPENED SEP 11, 2018Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 22, 2019

2123 S. Lenox St., Milwaukee, WI 53207 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,880$2,400Sep 21, 2018Final
Citation 1, item 1b
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Sep 21, 2018Final
Citation 1, item 1c
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$1,663$0Sep 21, 2018Final
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,880$2,400Sep 21, 2018Final
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Sep 21, 2018Final
Citation 1, item 3c
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Sep 21, 2018Final
Citation 2, item 1
29 CFR 1926.34(b) · Means of egress
Other-than-serious$0$0Sep 21, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.34 · Means of egress

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other new housing for-sale builders employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.