OSHA SearchOSHA records by employer

Rybovich Boat Company, LLC: OSHA inspections and violations

West Palm Beach, Florida · Marinas · NAICS 713930

2inspections
4citation items
$15,385current penalties
Jul 24, 2020last inspection

Rybovich Boat Company, LLC has 2 OSHA inspections on record in Florida, the first in 2011.

OSHA's last visit started on Jul 24, 2020 after a fatality or catastrophe, in West Palm Beach.

Across those inspections OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

OSHA proposed $19,953 in penalties. After settlements and reviews the total is $15,385, down 23%.

Most often, OSHA cited 1910.134, respiratory protection (2 items).

For context, across all arts and recreation employers the median penalty per cited inspection since 2015 is $1,400. Rybovich Boat Company, LLC averages $11,605 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Rybovich Boat Company, LLC also files yearly injury logs with OSHA, summarized below.

Rybovich Boat Company, LLC: OSHA citation items per year, 2011 to 2020
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

316employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Rybovich Boat Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344853494 OPENED JUL 24, 2020Closed

Fatality or catastrophe · Complete · Safety · 260 employees at the site · Closed Feb 11, 2022

4200 North Flagler Drive, West Palm Beach, FL 33407 · Marinas · OSHA's record · Phone and website on Google Maps

Incident on Jul 24, 2020 (fatal): Employee is electrocuted and is killed after contacting live

At 8:00 a.m. on July 24, 2020, an employee was working on live electrical wires energized with 480 volts/600 amps leading from an electrical pit to yacht power points on a marina dock to determine which lines were faulty. The employee's hand contacted a live wire while inside an electrical vault performing troubleshooting of the electrical wiring. The employee suffered an electrical shock and was pronounced dead at the site.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(2) · Working near live electrical parts
Serious$13,653$11,605Jan 19, 2021Final

Inspection 315353003 OPENED APR 27, 2011Closed

Referral · Partial · Safety · 228 employees at the site · Closed Jan 5, 2012

4200 North Flagler Drive, West Palm Beach, FL 33407 · Marinas · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$6,300$3,780Aug 24, 2011Closed
Citation 2, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Aug 24, 2011Closed
Citation 2, item 2
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Aug 24, 2011Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the West Palm Beach site logged 13 recordable injuries or illnesses among about 237 workers: 5.9 per 100 full-time workers, against a median of 3.8 for its industry. Those cases cost 14 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Rybovich Boat Company LLC
West Palm Beach · 2017
237 1325.93.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(2)

(2) Energized parts. If the exposed live parts are not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices shall be used to protect employees who may be exposed to the electrical hazards involved. Such work practices shall protect employees against contact with energized circuit parts directly with any part of their body or indirectly through some other conductive object. The work practices that are used shall be suitable for the conditions under which the work is to be performed and for the voltage level of the exposed electric conductors or circuit parts. Specific work practice requirements are detailed in paragraph (c) of this section.

OSH Act Section 5 · General Duty Clause

Other marinas employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.