OSHA SearchOSHA records by employer

Ryobi Die Casting: OSHA inspections and violations

Shelbyville, Indiana · Nonferrous Metal Foundries · NAICS 331521

4inspections
9citation items
$8,267current penalties
Jul 21, 2017last inspection

OSHA has inspected Ryobi Die Casting 4 times in Indiana since 1991.

The latest one began on Jul 21, 2017 after a complaint, in Shelbyville.

Those inspections ended with 9 citation items: 7 serious and 2 other-than-serious.

Penalties were first proposed at $14,250 and now stand at $8,267, 42% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Ryobi Die Casting averages $853 (2 cited inspections).

Ryobi Die Casting: OSHA citation items per year, 1991 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Ryobi Die Casting again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342491891 OPENED JUL 21, 2017Closed

Complaint · Partial · Health · 300 employees at the site · Closed Sep 13, 2017

800 West Mausoleum Road, Shelbyville, IN 46176 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,125$731Aug 16, 2017Final

Inspection 341111839 OPENED DEC 8, 2015Closed

Referral · Partial · Safety · 892 employees at the site · Closed Aug 3, 2016

800 West Mousoleum Road, Shelbyville, IN 46176 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(n)(2)(i) · Overhead and gantry cranes
Serious$1,500$975Apr 1, 2016Final

Inspection 317863009 OPENED FEB 26, 2015Closed

Referral · Partial · Safety · 100 employees at the site · Closed Apr 8, 2015

800 West Mausoleum Road, Shelbyville, IN 46176 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114964232 OPENED NOV 20, 1991Closed

Complaint · Complete · Safety · 180 employees at the site · Closed Feb 19, 1992

800 Mausoleum Rd, Shelbyville, IN 46176 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$1,875$937Jan 2, 1992Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,500$2,250Jan 2, 1992Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,500$1,500Jan 2, 1992Closed
Citation 1, item 4
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$1,875$937Jan 2, 1992Closed
Citation 1, item 5 Serious$1,875$937Jan 2, 1992Closed
Citation 2, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Jan 2, 1992Closed
Citation 2, item 2
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Jan 2, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(n)(2)(i)

(2) Attaching the load. (i) The hoist chain or hoist rope shall be free from kinks or twists and shall not be wrapped around the load.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.332 · Training

Other nonferrous metal foundries employers in Indiana