Inspection 343849923 OPENED MAR 14, 2019Closed
130 Goddard Memorial Dr, Worcester, MA 01603 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Worcester, Massachusetts · Machine Shops · NAICS 332710
Since 2018, OSHA inspectors have visited Saeilo Manufacturing Industries in Massachusetts 2 times.
The most recent inspection opened on Mar 14, 2019 to follow up on an earlier case, in Worcester.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $13,304; today they stand at $6,652, 50% less.
The rule cited most here is 1910.147 (lockout/tagout), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Saeilo Manufacturing Industries averages $6,652 across 1 cited inspection.
Massachusetts · latest 90 days of OSHA records
256employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Massachusetts
Checking a subcontractor, a client or your own company? Watch Saeilo Manufacturing Industries and get notified the morning OSHA posts a new citation for it.
Watch this company130 Goddard Memorial Dr, Worcester, MA 01603 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
130 Goddard Memorial Dr, Worcester, MA 01603 · Machine Shops · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $5,174 | $2,587 | Dec 13, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(4)(ii)(b) · Lockout/tagout |
Serious | $0 | $0 | Dec 13, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $5,174 | $2,587 | Dec 13, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $2,956 | $1,478 | Dec 13, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(ii)
(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)(b)
(B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.