OSHA SearchOSHA records by employer

Salas Homes LLC: OSHA inspections and violations

Las Cruces, New Mexico · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

3inspections
9citation items
$8,000current penalties
Sep 15, 2021last inspection

OSHA has inspected Salas Homes LLC 3 times in New Mexico since 2005.

The latest one began on Sep 15, 2021 as a planned inspection, in Las Cruces.

Those inspections ended with 9 citation items: 9 serious.

Penalties were first proposed at $15,250 and now stand at $8,000, 48% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Salas Homes LLC averages $3,625 (2 cited inspections).

Salas Homes LLC: OSHA citation items per year, 2005 to 2021
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Salas Homes LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345556831 OPENED SEP 15, 2021Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 4, 2022

4200 Northrise, Las Cruces, NM 88011 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,000$500Mar 16, 2022Final

Inspection 345262398 OPENED APR 15, 2021Closed

Referral · Partial · Safety · 9 employees at the site · Closed Nov 23, 2021

4201 Northrise (new Apartment Complex), Las Cruces, NM 88012 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(4) · Construction safety programs
Serious$3,000$1,500Oct 12, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$1,500Oct 12, 2021Final
Citation 1, item 3
29 CFR 1926.501(b)(2)(ii) · Fall protection in construction
Serious$3,000$1,500Oct 12, 2021Final
Citation 1, item 4
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,000$1,500Oct 12, 2021Final
Citation 1, item 5
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,500$750Oct 12, 2021Final

Inspection 307127712 OPENED JAN 7, 2005Closed

Referral · Complete · Safety · 6 employees at the site · Closed Jun 28, 2005

1300 Avenida De Mesilla, Las Cruces, NM 88001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$750$750Apr 7, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$0$0Apr 7, 2005Closed
Citation 1, item 1c
29 CFR 1926.451(g)(4)(ii) · Scaffolds, general requirements
Serious$0$0Apr 7, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(4)

(4) The employer shall permit only those employees qualified by training or experience to operate equipment and machinery.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other new single-family housing construction (except for-sale builders) employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.