OSHA SearchOSHA records by employer

Sawcross Inc.: OSHA inspections and violations

Jacksonville, Florida · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
4citation items
$44,006current penalties
Mar 13, 2025last inspection

Since 1999, OSHA inspectors have visited Sawcross Inc. in Florida 4 times.

The most recent inspection opened on Mar 13, 2025 after a fatality or catastrophe, in Orlando.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $48,895; today they stand at $44,006, 10% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sawcross Inc. averages $44,006 across 1 cited inspection.

Sawcross Inc. also files yearly injury logs with OSHA, summarized below.

Sawcross Inc.: OSHA citation items per year, 1999 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Sawcross Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348104274 OPENED MAR 13, 2025Closed

Fatality or catastrophe · Complete · Safety · 13 employees at the site · Closed Sep 11, 2025

5420 L B Mcleod Rd, Orlando, FL 32811 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$16,550$14,895Aug 8, 2025Final
Citation 1, item 2a
29 CFR 1926.651(c)(2) · Excavations
Serious$11,916$10,724Aug 8, 2025Final
Citation 1, item 2b
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$11,916$10,724Aug 8, 2025Final
Citation 1, item 3
29 CFR 1926.652(b)(1)(ii) · Trench protection
Serious$8,513$7,662Aug 8, 2025Final

Inspection 341939528 OPENED NOV 29, 2016Closed

Planned · No inspection · Safety · 5 employees at the site · Closed Dec 27, 2016

5000 Se 223rd St, Hawthorne, FL 32640 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339071177 OPENED MAY 16, 2013Closed

Planned · No inspection · Safety · Closed May 20, 2013

3016 Chief Ridaught Trl, Middleburg, FL 32068 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302733563 OPENED OCT 5, 1999Closed

Planned · No inspection · Safety · Closed Oct 5, 1999

1555 Milcoe Road, Jacksonville, FL 32225 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Jacksonville site logged 3 recordable injuries or illnesses among about 98 workers: 3.1 per 100 full-time workers, against a median of 3.0 for its industry. Those cases cost 30 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Sawcross, Inc
Jacksonville · 2025
98 313.13.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(b)(1)(ii)

(ii) Slopes specified in paragraph (b)(1)(i) of this section, shall be excavated to form configurations that are in accordance with the slopes shown for Type C soil in appendix B to this subpart.

OSH Act Section 5 · General Duty Clause

Other water and sewer line and related structures construction employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.