OSHA SearchOSHA records by employer

Sawdust and Splinters: OSHA inspections and violations

Gatesville, Texas · Nonupholstered Wood Household Furniture Manufacturing · NAICS 337122

2inspections
10citation items
$7,895current penalties
Jan 18, 2018last inspection

Since 2017, OSHA inspectors have visited Sawdust and Splinters in Texas 2 times.

The most recent inspection opened on Jan 18, 2018 to follow up on an earlier case, in Gatesville.

In all, OSHA issued 10 citation items: 5 serious and 5 other-than-serious.

The proposed penalties came to $13,158; today they stand at $7,895, 40% less.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Sawdust and Splinters averages $3,947 across 2 cited inspections.

Sawdust and Splinters: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Sawdust and Splinters and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342887981 OPENED JAN 18, 2018Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed Feb 6, 2018

3015 State Hwy 36, Gatesville, TX 76528 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$353$212Jan 24, 2018Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$353$212Jan 24, 2018Final

Inspection 342043106 OPENED JAN 20, 2017Closed

Complaint · Partial · Safety · 13 employees at the site · Closed Feb 17, 2017

3015 State Hwy 36, Gatesville, TX 76528 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.37(b)(2) · Exit routes
Serious$3,078$1,847Feb 1, 2017Final
Citation 1, item 1b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Feb 1, 2017Final
Citation 1, item 2
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$1,662$997Feb 1, 2017Final
Citation 1, item 3
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$4,563$2,738Feb 1, 2017Final
Citation 1, item 4
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$2,216$1,330Feb 1, 2017Final
Citation 2, item 1
29 CFR 1910.303(e) · Electrical equipment, general requirements
Other-than-serious$311$187Feb 1, 2017Final
Citation 2, item 2
29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods
Other-than-serious$311$187Feb 1, 2017Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$311$187Feb 1, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(q)(7)

(7) Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(d)(1)

(d) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws.

29 CFR 1910.213(p)(4)

(4) Belt sanding machines shall be provided with guards at each nip point where the sanding belt runs on to a pulley. These guards shall effectively prevent the hands or fingers of the operator from coming in contact with the nip points. The unused run of the sanding belt shall be guarded against accidental contact.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other nonupholstered wood household furniture manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.