Inspection 344199716 OPENED JUL 19, 2019Closed
6500 Se Johnson Creek Blvd, Portland, OR 97206 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected SC Concrete Products Inc 3 times in Oregon since 2019.
The latest one began on Jul 19, 2019 to follow up on an earlier case, in Portland.
Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.
Penalties were first proposed at $200 and still stand at $200.
Respiratory protection comes up most often in these citations: 2 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and SC Concrete Products Inc averages $100 (2 cited inspections).
Oregon · latest 90 days of OSHA records
397employers cited
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch SC Concrete Products Inc and get notified the morning OSHA posts a new citation for it.
Watch this company6500 Se Johnson Creek Blvd, Portland, OR 97206 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6500 Se Johnson Creek Blvd, Portland, OR 97206 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR OAR 437-002-1056(1) |
Serious | $100 | $100 | Jul 8, 2019 | Final |
| Citation 1, item 1b 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $0 | $0 | Jul 8, 2019 | Final |
| Citation 1, item 1c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Jul 8, 2019 | Final |
6500 Se Johnson Creek Blvd, Portland, OR 97206 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.140(d)(2)(ii) · Personal fall protection systems |
Serious | $100 | $100 | Jun 20, 2019 | Final |
| Citation 2, item 2 29 CFR OAR 437-001-0765(1)-3 |
Other-than-serious | $0 | $0 | Jun 20, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.140(d)(2)(ii)
(ii) Personal fall arrest systems are rigged in such a manner that the employee cannot free fall more than 6 feet (1.8 m) or contact a lower level. A free fall may be more than 6 feet (1.8 m) provided the employer can demonstrate the manufacturer designed the system to allow a free fall of more than 6 feet and tested the system to ensure a maximum arresting force of 1,800 pounds (8 kN) is not exceeded.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.