OSHA SearchOSHA records by employer

Schenker, Inc.: OSHA inspections and violations

Ridgeway, Virginia · All Other Miscellaneous General Purpose Machinery Manufacturing · NAICS 333999

2inspections
7citation items
$17,181current penalties
Jun 4, 2019last inspection

Since 2014, OSHA inspectors have visited Schenker, Inc. in Virginia 2 times.

The most recent inspection opened on Jun 4, 2019 as a planned inspection, in Winchester.

In all, OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

The proposed penalties came to $35,310; today they stand at $17,181, 51% less.

The rule cited most here is 1910.147 (lockout/tagout), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Schenker, Inc. averages $17,181 across 1 cited inspection.

Schenker, Inc. also files yearly injury logs with OSHA, summarized below.

Schenker, Inc.: OSHA citation items per year, 2014 to 2019
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Schenker, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344074257 OPENED JUN 4, 2019Closed

Planned · Partial · Health · 76 employees at the site · Closed Jan 31, 2020

291 Park Center Dr., Winchester, VA 22603 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$11,455$5,727Aug 6, 2019Final
Citation 1, item 2b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Aug 6, 2019Final
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Aug 6, 2019Final
Citation 1, item 3
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$11,455$5,727Aug 6, 2019Final
Citation 1, item 4
29 CFR 1910.151(b) · First aid and eyewash
Serious$11,455$5,727Aug 6, 2019Final

Inspection 317685998 OPENED APR 16, 2014Closed

Planned · Complete · Health · 37 employees at the site · Closed Jun 19, 2014

220 Fontaine Drive, Ridgeway, VA 24148 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$945$0Apr 21, 2014Closed
Citation 2, item 1
29 CFR 1910.37(b)(4) · Exit routes
Other-than-serious$0$0Apr 21, 2014Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Ridgeway site logged 0 recordable injuries or illnesses among about 38 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Schenker Inc.
Ridgeway · 2025
38 000.02.6
Schenker, Inc., Martinsville
Ridgeway · 2021
34 000.02.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

Other all other miscellaneous general purpose machinery manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.