Automated Conveyor Systems Inc.: OSHA inspections and violations
Lynchburg, Virginia · Conveyor and Conveying Equipment Manufacturing · NAICS 333922
10inspections
27citation items
$143,462current penalties
Feb 26, 2025last inspection
Automated Conveyor Systems Inc. has 10 OSHA inspections on record in Virginia, the first in 1986.
OSHA's last visit started on Feb 26, 2025 on a referral, in Lynchburg.
Across those inspections OSHA issued 27 citation items: 3 serious, 1 willful and 23 other-than-serious.
OSHA proposed $178,645 in penalties. After settlements and reviews the total is $143,462, down 20%.
Most often, OSHA cited 1910.106, flammable liquids (5 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Automated Conveyor Systems Inc. averages $47,083 over 3 cited inspections in that time.
Automated Conveyor Systems Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Virginia · latest 90 days of OSHA records
246employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Automated Conveyor Systems Inc. and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Lynchburg site logged 12 recordable injuries or illnesses among about 326 workers: 0.0 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 281 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Automated Conveyor Systems
Lynchburg · 2025
326
12
4
0.0
1.9
Automated Conveyor Systems, Inc.
Lynchburg · 2024
315
7
5
1.7
1.9
4533_10316
Lynchburg · 2021
250
10
6
3.1
1.9
Included with any plan: 5 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.