Port Richey, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

3inspections
9citation items
$4,501current penalties
Apr 11, 2018last inspection

Since 1976, OSHA inspectors have visited Schmitt Inc. in Florida 3 times.

The most recent inspection opened on Apr 11, 2018 as a planned inspection, in Wesley Chapel.

In all, OSHA issued 9 citation items: 1 serious and 8 other-than-serious.

The proposed penalties came to $12,674; today they stand at $4,501, 64% less.

The rule cited most here is 1910.252 (welding fire safety), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Schmitt Inc. averages $4,401 across 1 cited inspection.

Schmitt Inc.: OSHA citation items per year, 1976 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Schmitt Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343081055 OPENED APR 11, 2018Closed

Planned · Partial · Safety · 110 employees at the site · Closed Nov 13, 2018

4593 Tramanto Lane, Wesley Chapel, FL 33543 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$11,641$4,074Oct 3, 2018Final
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$933$327Oct 3, 2018Final

Inspection 14051346 OPENED MAR 13, 1978Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 24, 1978

Us 19 And Embassy Road, Port Richey, FL 33568 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.400(h)(1) · Introduction
Other-than-serious$0$0Mar 21, 1978Closed

Inspection 14071146 OPENED FEB 19, 1976Closed

Planned · Complete · Safety · 30 employees at the site · Closed Apr 7, 1976

900 Us Hwy 19 North, Port Richey, FL 33568 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Feb 25, 1976Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 25, 1976Closed
Citation 1, item 3
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Other-than-serious$0$0Feb 25, 1976Closed
Citation 1, item 4
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Feb 25, 1976Closed
Citation 1, item 5
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Feb 25, 1976Closed
Citation 1, item 6
29 CFR 1904.5(a) · Determination of work-relatedness
Other-than-serious$100$100Feb 25, 1976Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.5 · Determination of work-relatedness

29 CFR 1904.5(a)

(a) Basic requirement. You must consider an injury or illness to be work-related if an event or exposure in the work environment either caused or contributed to the resulting condition or significantly aggravated a pre-existing injury or illness. Work-relatedness is presumed for injuries and illnesses resulting from events or exposures occurring in the work environment, unless an exception in § 1904.5(b)(2) specifically applies.

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.252(a)(2)(iib)

(ii) Fire extinquishers. Suitable fire extinguishing equipment shall be maintained in a state of readiness for instant use. Such equipment may consist of pails of water, buckets of sand, hose or portable extinguishers depending upon the nature and quantity of the combustible material exposed.

29 CFR 1910.252(a)(2)(ivc)

(iv) Authorization. Before cutting or welding is permitted, the area shall be inspected by the individual responsible for authorizing cutting and welding operations. He shall designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.400 · Introduction