Inspection 345073159 OPENED DEC 15, 2020Closed
4537 Texas Street, Waterloo, IA 50702 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
Incident on Dec 14, 2020: Employee incurs burns and fractures ribs following explosion
At 12:52 p.m. on December 12, 2020, an incident occurred while preparing to replace fuel pumps inside a 93-gallon propane fuel tank assembly located on the rear underside of a school bus. As the bolts on the access port were loosened, propane vapors were released, causing the flammability range to exceed the lower explosive limit (LEL) of 2.15%. The released vapors contacted an electrical source, resulting in an explosion. The employee sustained burns and a broken rib due to the heat and air pressure from the explosion. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.307(c) · Hazardous (classified) locations |
Serious | $8,096 | $6,500 | Feb 8, 2021 | Final |