Inspection 344167960 OPENED JUL 25, 2019Closed
777 Talcottville Road, Vernon, CT 06066 · New Car Dealers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Vernon, Connecticut · New Car Dealers · NAICS 441110
OSHA has inspected Scranton Motors, Inc. 3 times in Connecticut since 1989.
The latest one began on Jul 25, 2019 to monitor an earlier case, in Vernon.
Those inspections ended with 20 citation items: 17 serious and 3 other-than-serious.
Penalties were first proposed at $10,735 and now stand at $9,435, 12% lower after settlements or reviews.
Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.
How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Scranton Motors, Inc. averages $6,255 (1 cited inspection).
Scranton Motors, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Connecticut · latest 90 days of OSHA records
89employers cited
Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Connecticut
Checking a subcontractor, a client or your own company? Watch Scranton Motors, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company777 Talcottville Road, Vernon, CT 06066 · New Car Dealers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
777 Talcottville Road, Vernon, CT 06066 · New Car Dealers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $3,381 | $3,381 | Aug 16, 2019 | Final |
| Citation 1, item 1b 29 CFR 1910.37(b)(6) · Exit routes |
Serious | $0 | $0 | Aug 16, 2019 | Final |
| Citation 1, item 2a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $2,874 | $2,874 | Aug 16, 2019 | Final |
| Citation 1, item 2b 29 CFR 1910.304(b)(4)(ii)(b) · Grounding and circuit protection |
Serious | $0 | $0 | Aug 16, 2019 | Final |
| Citation 1, item 2c 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $0 | $0 | Aug 16, 2019 | Final |
777 Talcottville Road, Vernon, CT 06066 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.94(c)(2) · Ventilation |
Serious | $480 | $380 | Oct 31, 1989 | Closed |
| Citation 1, item 2 29 CFR 1910.106(d)(4)(iii) · Flammable liquids |
Serious | $480 | $350 | Oct 31, 1989 | Closed |
| Citation 1, item 3 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Serious | $480 | $350 | Oct 31, 1989 | Closed |
| Citation 1, item 4 29 CFR 1910.107(c)(2) · Spray painting and finishing |
Serious | $480 | $350 | Oct 31, 1989 | Closed |
| Citation 1, item 5a 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $560 | $430 | Oct 31, 1989 | Closed |
| Citation 1, item 5b 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $0 | $0 | Oct 31, 1989 | Closed |
| Citation 1, item 6 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $480 | $350 | Oct 31, 1989 | Closed |
| Citation 1, item 7 29 CFR 1910.107(e)(9) · Spray painting and finishing |
Serious | $320 | $290 | Oct 31, 1989 | Closed |
| Citation 1, item 8 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Serious | $400 | $270 | Oct 31, 1989 | Closed |
| Citation 1, item 9 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Serious | $240 | $110 | Oct 31, 1989 | Closed |
| Citation 1, item 10 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $240 | $110 | Oct 31, 1989 | Closed |
| Citation 1, item 11 29 CFR 1910.1200(h)(2)(iii) · Hazard communication |
Serious | $240 | $110 | Oct 31, 1989 | Closed |
| Citation 2, item 1 29 CFR 1904.2(a) · Partial exemption for establishments in certain industries |
Other-than-serious | $80 | $80 | Oct 31, 1989 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Oct 31, 1989 | Closed |
| Citation 2, item 3 29 CFR 1910.252(e)(2)(iii) · Welding fire safety |
Other-than-serious | $0 | $0 | Oct 31, 1989 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Vernon site logged 2 recordable injuries or illnesses among about 57 workers: 14.4 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 2 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Scranton Motors Inc. Vernon · 2022 | 57 | 2 | 2 | 14.4 | 2.7 |
| Scranton Motors Inc Vernon · 2020 | 62 | 1 | 1 | 1.6 | 2.7 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Dec 7, 2018, Vernon: Hospitalization · soreness, pain, hurt-nonspecified injury · chest, except internal location of diseases or disorders
An employee had been heating a ball joint with a torch. A 2-inch piece of steel broke off and hit the employee in the chest.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.107(c)(2)
(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.
Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.