OSHA SearchOSHA records by employer

SDS Industries , Inc.: OSHA inspections and violations

Pacoima, California · Metal Window and Door Manufacturing · NAICS 332321

5inspections
24citation items
$16,500current penalties
Mar 5, 2020last inspection

Since 1988, OSHA inspectors have visited SDS Industries , Inc. in California 5 times.

The most recent inspection opened on Mar 5, 2020 as a planned inspection, in Pacoima.

In all, OSHA issued 24 citation items: 10 serious and 14 other-than-serious.

The proposed penalties came to $35,840; today they stand at $16,500, 54% less.

The rule cited most here is 1910.217 (mechanical power presses), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. SDS Industries , Inc. averages $7,620 across 2 cited inspections.

SDS Industries , Inc.: OSHA citation items per year, 1988 to 2020
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,130employers cited

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch SDS Industries , Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344680640 OPENED MAR 5, 2020Closed

Planned · Complete · Safety · 210 employees at the site · Closed Oct 18, 2021

10241 Norris Ave., Pacoima, CA 91331 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3241(A)
Other-than-serious$400$325Jul 2, 2020Final
Citation 1, item 2 Other-than-serious$200$160Jul 2, 2020Final
Citation 1, item 3
29 CFR 3209(A)
Other-than-serious$300$160Jul 2, 2020Final
Citation 1, item 4
29 CFR 3314(G)
Other-than-serious$600$160Jul 2, 2020Final
Citation 1, item 5
29 CFR 5144(C)
Other-than-serious$200$160Jul 2, 2020Final
Citation 1, item 6
29 CFR 6151(C)
Other-than-serious$200$160Jul 2, 2020Final
Citation 2, item 1
29 CFR 4184(B)
Serious$5,400$2,925Jul 2, 2020Final
Citation 3, item 1
29 CFR 4227(A)
Serious$3,600$2,925Jul 2, 2020Final
Citation 4, item 1
29 CFR 4211(A)
Serious$5,400$2,925Jul 2, 2020Final

Inspection 341084861 OPENED NOV 24, 2015Closed

Accident · Partial · Safety · 190 employees at the site · Closed Jan 3, 2017

10241 Norris Ave., Pacoima, CA 91331 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3314(G)(1)
Other-than-serious$280$280Apr 27, 2016Final
Citation 2, item 1
29 CFR 4199(A)
Serious$18,000$5,060Apr 27, 2016Final

Inspection 112226956 OPENED NOV 2, 1990Closed

Accident · Partial · Safety · 200 employees at the site · Closed Jan 29, 1991

12303 Montaque Lane, Pacoima, CA 91331 · OSHA's record · Phone and website on Google Maps

Incident on Sep 12, 1990: Employee's foot run over by forklift truck

EMPLOYEE #1 WAS WALKING BACK FROM GETTING A DRINK AND HAD SEEN AN EMPTY BOX IN T HE PATH OF A FORKLIFT. WHEN HE REMOVED IT, HE MISJUDGED THE SPEED OF THE FORKLIF T AND HIS FOOT WAS CAUGHT UNDER THE WHEEL OF THE MOVING VEHICLE, RESULTING IN A SEVERE LACERATION OF HIS MIDDLE TOE. THE EMPLOYEE WAS TREATED AND RELEASED. THER E WAS NO ACCIDENT RELATED VIOLATION CITED.

No citations from this inspection.

Inspection 106334352 OPENED APR 19, 1988Closed

Follow-up · Partial · Safety · 302 employees at the site · Closed Jun 15, 1988

12303 Montague Street, Pacoima, CA 91331 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106334410 OPENED FEB 23, 1988Closed

Planned · Complete · Safety · 302 employees at the site · Closed Jun 14, 1988

12303 Montague Street, Pacoima, CA 91331 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$280$280Mar 14, 1988Closed
Citation 1, item 2a
29 CFR 1910.110(f)(7) · Storage and handling of liquefied petroleum gases
Serious$210$210Mar 14, 1988Closed
Citation 1, item 2b
29 CFR 1910.110(g)(12)(vii) · Storage and handling of liquefied petroleum gases
Serious$0$0Mar 14, 1988Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$280$280Mar 14, 1988Closed
Citation 1, item 4
29 CFR 1910.217(c)(2)(vii) · Mechanical power presses
Serious$280$280Mar 14, 1988Closed
Citation 1, item 5
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$210$210Mar 14, 1988Closed
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 2
29 CFR 1910.217(b)(6)(i) · Mechanical power presses
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 3
29 CFR 1910.217(b)(7)(ii) · Mechanical power presses
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 4
29 CFR 1910.217(d)(4) · Mechanical power presses
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 5a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 5b
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Mar 14, 1988Closed
Citation 2, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Mar 14, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.110(f)(7)

(7) Fire protection. Storage locations other than supply depots separated and located apart from dealer, reseller, or user establishments shall be provided with at least one approved portable fire extinguisher having a minimum rating of 8-B, C.

29 CFR 1910.110(g)(12)(vii)

(g) [Reserved]

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 2473.1

Other metal window and door manufacturing employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.