Seabrook Marine LLC: OSHA inspections and violations

New Orleans, Louisiana · Boat Building · NAICS 336612

1inspections
5citation items
$2,640current penalties
Nov 4, 2015last inspection

OSHA inspectors have visited Seabrook Marine LLC in Louisiana one time.

It opened on Nov 4, 2015 as a planned inspection, in New Orleans.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $4,400; today they stand at $2,640, 40% less.

The rule cited most here is 1910.107 (spray painting and finishing), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Seabrook Marine LLC averages $2,640 across 1 cited inspection.

Seabrook Marine LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Seabrook Marine LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341035061 OPENED NOV 4, 2015Closed

Planned · Partial · Health · 20 employees at the site · Closed Feb 25, 2016

5801 France Road, New Orleans, LA 70126 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(3) · Spray painting and finishing
Serious$1,600$960Dec 15, 2015Final
Citation 1, item 2a
29 CFR 1910.107(d)(5) · Spray painting and finishing
Serious$1,600$960Dec 15, 2015Final
Citation 1, item 2b
29 CFR 1910.107(d)(7) · Spray painting and finishing
Serious$0$0Dec 15, 2015Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,200$720Dec 15, 2015Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Dec 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(3)

(3) Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.

29 CFR 1910.107(d)(5)

(5) Electric motors. Electric motors driving exhaust fans shall not be placed inside booths or ducts. See also paragraph (c) of this section.

29 CFR 1910.107(d)(7)

(7) Exhaust ducts. Exhaust ducts shall be constructed of steel and shall be substantially supported. Exhaust ducts without dampers are preferred; however, if dampers are installed, they shall be maintained so that they will be in a full open position at all times the ventilating system is in operation.

29 CFR 1910.134 · Respiratory protection