OSHA SearchOSHA records by employer

Seaport Masonry, Inc.: OSHA inspections and violations

Scituate, Massachusetts · Masonry Contractors · NAICS 238140

2inspections
5citation items
$15,010current penalties
Nov 4, 2025last inspection

OSHA has inspected Seaport Masonry, Inc. 2 times in Massachusetts since 2022.

The latest one began on Nov 4, 2025 after a complaint, in Boston.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $35,418 and now stand at $15,010, 58% lower after settlements or reviews.

Confined Spaces in Construction: general requirements comes up most often in these citations: 3 items under 1926.1203.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Seaport Masonry, Inc. averages $7,505 (2 cited inspections).

Seaport Masonry, Inc.: OSHA citation items per year, 2022 to 2025
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Seaport Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348580176 OPENED NOV 4, 2025Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Apr 9, 2026

25 Isabella St., Boston, MA 02116 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$4,965$10Mar 19, 2026Final

Inspection 345754998 OPENED JAN 31, 2022Closed

Referral · Partial · Health · 8 employees at the site · Closed Sep 4, 2024

7 Diane Terrace, Scituate, MA 02066 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Serious$10,151$7,500Jul 21, 2022Final
Citation 1, item 2b
29 CFR 1926.1203(b)(1) · Confined Spaces in Construction: general requirements
Serious$0$0Jul 21, 2022Final
Citation 1, item 3
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Serious$10,151$7,500Jul 21, 2022Final
Citation 1, item 4 Serious$10,151$0Jul 21, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.1203(b)(1)

(1) Inform exposed employees by posting danger signs or by any other equally effective means, of the existence and location of, and the danger posed by, each permit space; and

29 CFR 1926.1203(d)

(d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with § 1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives.

29 CFR 1926.1207 · Training

29 CFR 1926.20 · Construction safety programs

Other masonry contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.