OSHA SearchOSHA records by employer

Sesolinc GRP, Inc.: OSHA inspections and violations

Statesboro, Georgia · Other Metal Container Manufacturing · NAICS 332439

3inspections
19citation items
$15,849current penalties
Sep 17, 2025last inspection

Since 2014, OSHA inspectors have visited Sesolinc GRP, Inc. in Georgia 3 times.

The most recent inspection opened on Sep 17, 2025 as a planned inspection, in Statesboro.

In all, OSHA issued 19 citation items: 10 serious and 9 other-than-serious.

The proposed penalties came to $27,690; today they stand at $15,849, 43% less.

The rule cited most here is 1910.134 (respiratory protection), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Sesolinc GRP, Inc. averages $1,809 across 1 cited inspection.

Sesolinc GRP, Inc. also files yearly injury logs with OSHA, summarized below.

Sesolinc GRP, Inc.: OSHA citation items per year, 2014 to 2025
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Sesolinc GRP, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348514191 OPENED SEP 17, 2025Closed

Planned · Complete · Safety · 18 employees at the site · Closed Mar 4, 2026

304 South Randy Lowery Rd., Statesboro, GA 30461 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,015$1,809Feb 9, 2026Final
Citation 2, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 9, 2026Final

Inspection 339617680 OPENED MAR 6, 2014Closed

Complaint · Partial · Safety · 23 employees at the site · Closed Oct 20, 2014

806 Randy Lowery Road, Statesboro, GA 30461 · Other Metal Container Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$2,380$2,100Aug 22, 2014Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$4,900$2,100Aug 22, 2014Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Aug 22, 2014Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,900$2,100Aug 22, 2014Final
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$2,380$2,100Aug 22, 2014Final
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,380$2,100Aug 22, 2014Final
Citation 1, item 5b
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Aug 22, 2014Final
Citation 1, item 7
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,785$0Aug 22, 2014Final

Inspection 339623266 OPENED MAR 6, 2014Closed

Complaint · Partial · Health · 23 employees at the site · Closed Aug 20, 2014

806 Randy Lowery Road, Statesboro, GA 30461 · Other Metal Container Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Serious$1,785$975Jul 18, 2014Final
Citation 1, item 2a
29 CFR 1910.107(c)(5) · Spray painting and finishing
Other-than-serious$3,570$985Jul 18, 2014Final
Citation 1, item 2b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$985Jul 18, 2014Final
Citation 1, item 2c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jul 18, 2014Final
Citation 2, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$595$595Jul 18, 2014Final
Citation 2, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Jul 18, 2014Final
Citation 2, item 1c
29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection
Other-than-serious$0$0Jul 18, 2014Final
Citation 2, item 1d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Jul 18, 2014Final
Citation 2, item 1e
29 CFR 1910.134(k)(1)(v) · Respiratory protection
Other-than-serious$0$0Jul 18, 2014Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Statesboro site logged 1 recordable injury or illness among about 15 workers: 7.6 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Sesolinc GRP., Inc
Statesboro · 2025
15 107.63.6
Sesolinc GRP., Inc.
Statesboro · 2023
21 4219.43.6

Included with any plan: 2 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other other metal container manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.