OSHA SearchOSHA records by employer

Sewing Collection Inc: OSHA inspections and violations

Columbus, Ohio · All Other Miscellaneous Waste Management Services · NAICS 562998

3inspections
23citation items
$111,934current penalties
Aug 18, 2023last inspection

Sewing Collection Inc has 3 OSHA inspections on record in Ohio, the first in 2018.

OSHA's last visit started on Aug 18, 2023 after a complaint, in Columbus.

Across those inspections OSHA issued 23 citation items: 14 serious, 4 repeat and 5 other-than-serious.

OSHA proposed $210,137 in penalties. After settlements and reviews the total is $111,934, down 47%.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Sewing Collection Inc averages $55,967 over 2 cited inspections in that time.

Sewing Collection Inc: OSHA citation items per year, 2018 to 2023
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Sewing Collection Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346919269 OPENED AUG 18, 2023Closed

Complaint · Partial · Safety · 202 employees at the site · Closed Dec 4, 2023

3750 Courtright Ct, Columbus, OH 43227 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$8,840$5,304Oct 27, 2023Final
Citation 1, item 1b
29 CFR 1910.22(d)(1) · Walking-working surfaces
Serious$0$0Oct 27, 2023Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$11,050$6,630Oct 27, 2023Final

Inspection 343220901 OPENED JUN 12, 2018Closed

Referral · Partial · Health · 48 employees at the site · Closed Jul 3, 2018

2140 Refugee Rd, Columbus, OH 43207 · All Other Miscellaneous Waste Management Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343073441 OPENED APR 9, 2018Closed

Complaint · Partial · Safety · 48 employees at the site · Closed Apr 22, 2025

2140 Refugee Rd, Columbus, OH 43207 · All Other Miscellaneous Waste Management Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Other-than-serious$7,317$500Jul 30, 2018Final
Citation 1, item 2
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$5,488$1,500Jul 30, 2018Final
Citation 1, item 3
29 CFR 1910.36(d)(1) · Exit route design
Serious$9,147$4,000Jul 30, 2018Final
Citation 1, item 4
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$12,805$7,500Jul 30, 2018Final
Citation 1, item 5
29 CFR 1910.176(b) · Material storage and aisles
Serious$9,147$4,000Jul 30, 2018Final
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$9,147$500Jul 30, 2018Final
Citation 1, item 7a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$12,805$7,500Jul 30, 2018Final
Citation 1, item 7b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 30, 2018Final
Citation 1, item 8
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$12,805$7,500Jul 30, 2018Final
Citation 1, item 9
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$5,488$500Jul 30, 2018Final
Citation 1, item 10a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$9,147$4,000Jul 30, 2018Final
Citation 1, item 10b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Jul 30, 2018Final
Citation 1, item 10c
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Jul 30, 2018Final
Citation 1, item 11a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$9,147$500Jul 30, 2018Final
Citation 1, item 11b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jul 30, 2018Final
Citation 2, item 1
29 CFR 1910.37(b)(4) · Exit routes
Repeat$18,293$12,000Jul 30, 2018Final
Citation 2, item 2a
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Repeat$25,609$17,000Jul 30, 2018Final
Citation 2, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Repeat$25,609$20,000Jul 30, 2018Final
Citation 2, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Repeat$18,293$13,000Jul 30, 2018Final
Citation 3, item 1
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 30, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other all other miscellaneous waste management services employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.