OSHA SearchOSHA records by employer

Shawangunk TN HWY Dept: OSHA inspections and violations

Wallkill, New York · Highway, Street, and Bridge Construction · NAICS 237310

9inspections
37citation items
$0current penalties
Feb 26, 2016last inspection

Shawangunk TN HWY Dept has 9 OSHA inspections on record in New York, the first in 1997.

OSHA's last visit started on Feb 26, 2016 to follow up on an earlier case, in Wallkill.

Across those inspections OSHA issued 37 citation items: 28 serious and 9 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.253, gas welding and cutting (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Shawangunk TN HWY Dept averages $0 over 1 cited inspection in that time.

Shawangunk TN HWY Dept: OSHA citation items per year, 1997 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

21 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Shawangunk TN HWY Dept and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341281152 OPENED FEB 26, 2016Closed

Follow-up · Partial · Safety · Local government · 12 employees at the site · Closed May 2, 2016

16 Kings Lane, Wallkill, NY 12589 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340890128 OPENED AUG 31, 2015Closed

Planned · Complete · Safety · Local government · 12 employees at the site · Closed May 2, 2016

16 Kings Lane, Wallkill, NY 12589 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR NYSLL ARTICLE 2, SECTION 27-A.3.A
Serious$0$0Nov 18, 2015Final
Citation 1, item 2
29 CFR 1910.22(d)(1) · General requirements
Serious$0$0Nov 18, 2015Final
Citation 1, item 3
29 CFR 1910.36(d)(1) · Exit route design
Serious$0$0Nov 18, 2015Final
Citation 1, item 4
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Nov 18, 2015Final
Citation 1, item 5
29 CFR 1910.106(g)(9) · Flammable liquids
Serious$0$0Nov 18, 2015Final
Citation 1, item 6
29 CFR 1910.120(q)(6)(i) · Hazardous waste operations and emergency response
Serious$0$0Nov 18, 2015Final
Citation 1, item 7
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Nov 18, 2015Final
Citation 1, item 8
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0Nov 18, 2015Final
Citation 1, item 9
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Nov 18, 2015Final
Citation 1, item 10
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Nov 18, 2015Final
Citation 1, item 11
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Serious$0$0Nov 18, 2015Final
Citation 1, item 12
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$0$0Nov 18, 2015Final
Citation 1, item 13
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Nov 18, 2015Final
Citation 1, item 14
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Nov 18, 2015Final
Citation 1, item 15
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Serious$0$0Nov 18, 2015Final
Citation 1, item 16
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Nov 18, 2015Final
Citation 1, item 17
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Nov 18, 2015Final
Citation 1, item 18
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Nov 18, 2015Final
Citation 2, item 1
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Nov 18, 2015Final

Inspection 313869547 OPENED MAR 29, 2012Closed

Referral · Partial · Safety · Local government · 11 employees at the site · Closed May 17, 2012

16 Kings Lane, Wallkill, NY 12589 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309394757 OPENED APR 19, 2006Closed

Follow-up · Partial · Health · Local government · 12 employees at the site · Closed Apr 19, 2006

16 Kings Lane, Wallkill, NY 12589 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309394443 OPENED FEB 28, 2006Closed

Planned · Complete · Health · Local government · 12 employees at the site · Closed Apr 19, 2006

16 Kings Lane, Wallkill, NY 12589 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Mar 20, 2006Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Mar 20, 2006Closed
Citation 1, item 3
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Mar 20, 2006Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Mar 20, 2006Closed
Citation 2, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Mar 20, 2006Closed
Citation 2, item 3
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Mar 20, 2006Closed
Citation 2, item 4
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Mar 20, 2006Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 20, 2006Closed
Citation 2, item 6
29 CFR 8010029 A
Other-than-serious$0$0Mar 20, 2006Closed

Inspection 301474797 OPENED SEP 8, 1999Closed

Follow-up · Partial · Safety · Local government · 11 employees at the site · Closed Sep 23, 1999

16 Kings Lane, Wallkill, NY 12589 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124499914 OPENED FEB 23, 1999Closed

Complaint · Partial · Safety · Local government · 11 employees at the site · Closed Sep 23, 1999

16 Kings Lane, Wallkill, NY 12589 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.601(b)(14) · Motor vehicles
Serious$0$0Aug 19, 1999Closed
Citation 2, item 1
29 CFR 8010006 B
Other-than-serious$0$0Aug 19, 1999Closed

Inspection 124470550 OPENED SEP 23, 1997Closed

Follow-up · Partial · Health · Local government · 12 employees at the site · Closed Sep 24, 1997

16 Kings Lane, Wallkill, NY 12589 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 124468398 OPENED APR 21, 1997Closed

Planned · Complete · Health · Local government · 12 employees at the site · Closed Sep 24, 1997

16 Kings Lane, Wallkill, NY 12589 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Serious$0$0May 2, 1997Closed
Citation 1, item 2
29 CFR 1910.37(k)(2) · Exit routes
Serious$0$0May 2, 1997Closed
Citation 1, item 3
29 CFR 1910.106(g)(3)(ivd) · Flammable liquids
Serious$0$0May 2, 1997Closed
Citation 1, item 4
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0May 2, 1997Closed
Citation 1, item 5
29 CFR 1910.107(d)(4) · Spray painting and finishing
Serious$0$0May 2, 1997Closed
Citation 1, item 6
29 CFR 1910.120(q)(6) · Hazardous waste operations and emergency response
Serious$0$0May 2, 1997Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0May 2, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(3)(ivd)

(iv) Dispensing units. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be transferred from tanks by means of fixed pumps so designed and equipped as to allow control of the flow and to prevent leakage or accidental discharge.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.601 · Motor vehicles