OSHA SearchOSHA records by employer

Shelburne Limestone Corporation: OSHA inspections and violations

Colchester, Vermont · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

3inspections
10citation items
$12,996current penalties
Nov 16, 2020last inspection

OSHA has inspected Shelburne Limestone Corporation 3 times in Vermont since 2017.

The latest one began on Nov 16, 2020 on a referral, in Colchester.

Those inspections ended with 10 citation items: 7 serious and 3 other-than-serious.

Penalties were first proposed at $21,092 and now stand at $12,996, 38% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 3 items under 1910.1200.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Shelburne Limestone Corporation averages $6,498 (2 cited inspections).

Shelburne Limestone Corporation: OSHA citation items per year, 2017 to 2020
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Shelburne Limestone Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345024228 OPENED NOV 16, 2020Closed

Referral · Partial · Safety · 3 employees at the site · Closed May 12, 2021

1949 Main Street, Colchester, VT 05446 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Nov 12, 2020: Employee suffers electrical burns after contact with energiz

At 2:30 p.m. on November 12, 2020, an employee cut a neutral wire to install a new power whip for LED lighting. The employee was standing on a 6 foot step ladder while stripping the wire and contacted a 277 volt energized line within the ceiling. The employee's hands were burned, and he fell off the ladder. The employee sustained electrical burns to his right and left hands, as well as head lacerations due to the fall. The employee was treated without hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$8,096$4,048Mar 24, 2021Final
Citation 1, item 2a
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$8,096$4,048Mar 24, 2021Final
Citation 1, item 2b
29 CFR 1910.333(b)(2) · Working near live electrical parts
Serious$0$0Mar 24, 2021Final

Inspection 343161667 OPENED MAY 15, 2018Closed

Follow-up · Partial · Safety · 65 employees at the site · Closed May 24, 2018

1949 Main Street, Colchester, VT 05446 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342639663 OPENED SEP 8, 2017Closed

Programmed other · Complete · Health · 53 employees at the site · Closed May 21, 2018

1949 Main Street, Colchester, VT 05446 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$2,100$2,100Jan 24, 2018Final
Citation 1, item 2a
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$2,800$2,800Jan 24, 2018Final
Citation 1, item 2b
29 CFR 1910.1200(f)(6) · Hazard communication
Serious$0$0Jan 24, 2018Final
Citation 1, item 2c
29 CFR 1910.1200(j)(1) · Hazard communication
Serious$0$0Jan 24, 2018Final
Citation 2, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jan 24, 2018Final
Citation 2, item 2
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Jan 24, 2018Final
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.1200(j)(1)

(j) Dates—(1) Effective date. This section shall become effective July 19, 2024.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.