Shermco Industries, Co. has 6 OSHA inspections on record in Texas, the first in 1976.
OSHA's last visit started on Mar 21, 2023 after a fatality or catastrophe, in Irving.
Across those inspections OSHA issued 12 citation items: 2 serious and 10 other-than-serious.
OSHA proposed $56,045 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.309, (2 items).
For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,821. Shermco Industries, Co. averages $18,622 over 3 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Shermco Industries, Co. also files yearly injury logs with OSHA, summarized below.
It reported 3 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
401employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
Incident on Mar 20, 2023 (fatal): Employee is killed when caught in rotating part of lathe
At 10:15 p.m. on March 20, 2023, an employee was polishing a rotor shaft on a lathe. The employee became caught in the lathe. The employee sustained multiple broken bones and lacerations, leading to death. The employee also sustained head injuries.
Incident on Dec 19, 2020: Employee experiences electrical contact/arc event leading to
At 9:18 a.m. on December 19, 2020, an employee was conducting visual inspections of electrical equipment, specifically inspecting the backside of the breakers within the doghouse panels. While working alone, the employee was found with his upper body inside the back panel of the main breaker for the doghouse, with his head positioned between two phases of the breaker, each carrying 1,480 volts. An electrical contact/arc event occurred at the employee's head and both hands. The primary feed could not be shut off, and the secondary feed within the doghouse had been tripped, allowing 1,480 volts across three phases to enter the back of the main breaker while the rest of the doghouse and the plant remained deenergized. The incident resulted in electrical burns to both hands and a large cauterized laceration on the right hand, leading to the amputation of both hands. The employee was hospitalized.
Incident on Feb 15, 2018: Employee burns arms during electric arc flash
At 2:30 p.m. on February 15, 2018, an employee was adjusting an electrical boot and burned his arm when he was struck during an electric arc flash. The employee was hospitalized.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Irving site logged 4 recordable injuries or illnesses among about 1,070 workers: 0.3 per 100 full-time workers, against a median of 1.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Shermco Industries, Inc.
Irving · 2025
1,070
4
0
0.3
1.4
SI Wind and Motor Services, LLC
Irving · 2025
139
2
1
1.6
1.5
Shermco Industries
Irving · 2021
280
0
0
0.0
1.4
Included with any plan: 4 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was inspecting the doghouse panels for the backsides of breakers in a doghouse. An arc flash burned both the employee's hands, causing a large cauterized laceration to the right hand. Both hands were amputated.
An employee had set down an electrical breaker box inside a motor control center he was preparing to replace the breaker in. He turned to walk away and an electrical arc flashed out of the open door of the cabinet, burning his palms and wrist and causing a slight burn to his right cheek.
An employee was testing electrical cables. An arc flash occurred while the employee was putting rubber boots back on resulting in an electrical burn to the left arm.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.2 · Partial exemption for establishments in certain industries
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.