OSHA SearchOSHA records by employer

Shoreline Electric Inc.: OSHA inspections and violations

Las Vegas, Nevada · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

6inspections
8citation items
$2,600current penalties
Nov 6, 2023last inspection

Shoreline Electric Inc. has 6 OSHA inspections on record in Nevada, the first in 2009.

OSHA's last visit started on Nov 6, 2023, in Las Vegas.

Across those inspections OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

OSHA proposed $5,648 in penalties. After settlements and reviews the total is $2,600, down 54%.

Most often, OSHA cited 1904.32, yearly injury summary (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Shoreline Electric Inc. averages $1,000 over 1 cited inspection in that time.

Shoreline Electric Inc.: OSHA citation items per year, 2009 to 2023
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

112employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Shoreline Electric Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347087801 OPENED NOV 6, 2023Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Dec 21, 2023

9855 Gilespie Street, Las Vegas, NV 89183 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344804950 OPENED APR 28, 2020Closed

Unprogrammed related · Partial · Health · 2 employees at the site · Closed Oct 22, 2020

10835 South Eastern Avenue, Henderson, NV 89052 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR NEVADA REVISED STATUTES 618.375(2
Other-than-serious$4,048$1,000Aug 31, 2020Final

Inspection 313970923 OPENED FEB 10, 2010Closed

Follow-up · No inspection · Safety · 20 employees at the site · Closed Mar 10, 2010

6390 Boulder Highway, Las Vegas, NV 89122 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313445470 OPENED OCT 7, 2009Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 19, 2016

6390 Boulder Highway, Las Vegas, NV 89122 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$375$375Nov 25, 2009Closed
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$375$375Nov 25, 2009Closed
Citation 1, item 3
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$375$375Nov 25, 2009Closed
Citation 1, item 4
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$375$375Nov 25, 2009Closed

Inspection 312901184 OPENED MAR 13, 2009Closed

Complaint · Partial · Safety · 18 employees at the site · Closed May 15, 2009

6355 Shatz Street, Las Vegas, NV 89115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$100$100Apr 2, 2009Closed

Inspection 312897358 OPENED JAN 29, 2009Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 19, 2009

6355 Shatz Street, Las Vegas, NV 89115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.32(b)(2)(i) · Yearly injury summary
Other-than-serious$0$0Feb 13, 2009Closed
Citation 1, item 2
29 CFR 1904.32(b)(3) · Yearly injury summary
Other-than-serious$0$0Feb 13, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(2)(i)

(i) Total the columns on the OSHA 300 Log (if you had no recordable cases, enter zeros for each column total); and

29 CFR 1904.32(b)(3)

(3) How do I certify the annual summary? A company executive must certify that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other electrical contractors and other wiring installation contractors employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.