OSHA SearchOSHA records by employer

Showcase Kitchens, Inc.: OSHA inspections and violations

Green Bay, Wisconsin · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

9inspections
34citation items
$12,090current penalties
Feb 15, 2019last inspection

Since 1990, OSHA inspectors have visited Showcase Kitchens, Inc. in Wisconsin 9 times.

The most recent inspection opened on Feb 15, 2019 to monitor an earlier case, in Green Bay.

In all, OSHA issued 34 citation items: 22 serious, 2 repeat and 10 other-than-serious.

The proposed penalties came to $24,285; today they stand at $12,090, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 8 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Showcase Kitchens, Inc. averages $7,105 across 1 cited inspection.

Showcase Kitchens, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Showcase Kitchens, Inc.: OSHA citation items per year, 1990 to 2019
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Showcase Kitchens, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343788147 OPENED FEB 15, 2019Closed

Monitoring · Partial · Safety · 90 employees at the site · Closed Feb 15, 2019

3255 Yeager Dr., Green Bay, WI 54311 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341082352 OPENED NOV 24, 2015Closed

Referral · Partial · Safety · 70 employees at the site · Closed Apr 6, 2016

3255 Yeager Drive, Green Bay, WI 54311 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$2,975$2,082Dec 22, 2015Final
Citation 1, item 2
29 CFR 1910.213(m)(1) · Woodworking machinery
Serious$2,975$2,082Dec 22, 2015Final
Citation 1, item 3
29 CFR 1910.147(d) · Lockout/tagout
Serious$4,900$2,940Dec 22, 2015Final

Inspection 309836781 OPENED DEC 6, 2006Closed

Planned · Complete · Safety · 65 employees at the site · Closed Dec 28, 2006

3255 Yeager Dr, Green Bay, WI 54311 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$700$490Dec 11, 2006Closed

Inspection 306802216 OPENED JAN 26, 2006Closed

Planned · Partial · Safety · 60 employees at the site · Closed Mar 20, 2006

3255 Yeager Dr, Green Bay, WI 54311 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$525$250Feb 3, 2006Closed
Citation 1, item 1b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$0$0Feb 3, 2006Closed
Citation 1, item 2
29 CFR 1910.213(r)(4) · Woodworking machinery
Serious$700$350Feb 3, 2006Closed

Inspection 114154701 OPENED JUL 30, 1997Closed

Follow-up · Partial · Health · 65 employees at the site · Closed Sep 29, 1997

2674 S. Packerland Drive, Green Bay, WI 54313 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h) · Hazard communication
Repeat$120$120Sep 5, 1997Closed

Inspection 122476617 OPENED JAN 22, 1997Closed

Monitoring · Partial · Health · 55 employees at the site · Closed Apr 21, 1997

2674 S. Packerland Drive, Green Bay, WI 54313 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.307(c) · Hazardous (classified) locations
Other-than-serious$0$0Mar 7, 1997Closed

Inspection 114157886 OPENED FEB 13, 1996Closed

Complaint · Partial · Health · 65 employees at the site · Closed Nov 12, 1997

2674 S. Packerland Drive, Green Bay, WI 54313 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$900$0Apr 3, 1996Final
Citation 1, item 2
29 CFR 1910.138(a) · Gloves and hand protection
Serious$900$300Apr 3, 1996Final
Citation 1, item 3
29 CFR 1910.141(g)(2) · Sanitation
Serious$900$50Apr 3, 1996Final
Citation 1, item 5a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,200$300Apr 3, 1996Final
Citation 1, item 5b
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Apr 3, 1996Final
Citation 1, item 6a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$1,200$300Apr 3, 1996Final
Citation 1, item 6b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Apr 3, 1996Final
Citation 1, item 7a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$900$0Apr 3, 1996Final
Citation 1, item 7b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Apr 3, 1996Final
Citation 1, item 8a
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$1,200$300Apr 3, 1996Final
Citation 1, item 8b
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$0$0Apr 3, 1996Final
Citation 1, item 9a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$900$400Apr 3, 1996Final
Citation 1, item 9b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Apr 3, 1996Final
Citation 1, item 9c
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Apr 3, 1996Final
Citation 2, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Apr 3, 1996Final
Citation 2, item 2
29 CFR 1910.134(b)(8) · Respiratory protection
Other-than-serious$0$0Apr 3, 1996Final

Inspection 106510563 OPENED MAR 12, 1993Closed

Complaint · Complete · Safety · 65 employees at the site · Closed Jun 10, 1993

2674 S. Packerland Drive, Green Bay, WI 54313 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(b)(6) · Respiratory protection
Serious$525$250Apr 16, 1993Closed
Citation 1, item 2a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$525$275Apr 16, 1993Closed
Citation 1, item 2b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$0$0Apr 15, 1993Closed
Citation 2, item 1
29 CFR 1910.107(c)(7) · Spray painting and finishing
Other-than-serious$0$0Apr 16, 1993Closed
Citation 2, item 2
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Apr 16, 1993Closed
Citation 2, item 3
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Apr 16, 1993Closed
Citation 2, item 4
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Apr 16, 1993Closed
1 older inspection

Inspection 103050506 OPENED AUG 29, 1990Closed

Complaint · Partial · Safety · 62 employees at the site · Closed Jan 31, 1991

2674 S. Packerland Drive, Green Bay, WI 54313 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$320$200Sep 11, 1990Closed
Citation 2, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Repeat$1,920$1,400Sep 11, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Green Bay site logged 1 recordable injury or illness among about 105 workers: 1.1 per 100 full-time workers, against a median of 3.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Showcase
Green Bay · 2025
105 101.13.7

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Aug 30, 2017, Green Bay: Hospitalization · soreness, pain, hurt-nonspecified injury · multiple body parts, n.e.c.

On August 30, 2017, an employee was helping coworkers unload a cabinet from a truck and onto a ramp when he fell off the side of the ramp and struck the ground, injuring his collarbone and ribs.

Nov 19, 2015, Green Bay: Amputation · amputations · finger(s), fingernail(s), n.e.c.

On November 19, 2015, an employee was using a hand held air blower to clean wood chips off a shaper table while the cutter head was running. The employee's hand made contact with the cutting head, amputating the right index finger and severely lacerating the right thumb.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other wood kitchen cabinet and countertop manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.