Inspection 341597367 OPENED JUN 29, 2016Closed
100 Tait Street, Metlakatla, AK 99926 · Seafood Product Preparation and Packaging · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Serious | $2,550 | $1,275 | Jul 26, 2016 | Final |
| Citation 1, item 2a 29 CFR 1910.212(a)(2) · Machine guarding |
Serious | $4,250 | $2,125 | Jul 26, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $2,550 | $1,275 | Jul 26, 2016 | Final |
| Citation 1, item 4a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $2,550 | $1,275 | Jul 26, 2016 | Final |
| Citation 1, item 4b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 5a 29 CFR 1910.303(g)(1)(i)(b) · Electrical equipment, general requirements |
Serious | $2,550 | $1,275 | Jul 26, 2016 | Final |
| Citation 1, item 5b 29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 6a 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $2,550 | $1,275 | Jul 26, 2016 | Final |
| Citation 1, item 6b 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Jul 26, 2016 | Final |