Inspection 343184214 OPENED MAY 25, 2018Closed
100 Panton Road, Vergennes, VT 05491 · Other Aircraft Parts and Auxiliary Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Simmonds Precision Products Inc has 4 OSHA inspections on record in Vermont, the first in 1983.
OSHA's last visit started on May 25, 2018 after a complaint, in Vergennes.
Across those inspections OSHA issued 65 citation items: 10 serious and 55 other-than-serious.
OSHA proposed $26,250 in penalties. After settlements and reviews the total is $15,870, down 40%.
Most often, OSHA cited 1910.305, electrical wiring methods (9 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Simmonds Precision Products Inc averages $15,210 over 1 cited inspection in that time.
Simmonds Precision Products Inc also files yearly injury logs with OSHA, summarized below.
Vermont · latest 90 days of OSHA records
24employers cited
Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Vermont
Checking a subcontractor, a client or your own company? Watch Simmonds Precision Products Inc and get notified the morning OSHA posts a new citation for it.
Watch this company100 Panton Road, Vergennes, VT 05491 · Other Aircraft Parts and Auxiliary Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Panton Road, Vergennes, VT 05491 · Other Aircraft Parts and Auxiliary Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Dec 8, 2017: Employee is hospitalized after aluminum dust collector explo
At 12:00 p.m. on December 8, 2017, Employee #1 was adjusting a new sanding belt onto a horizontal belt sander that was serviced by the dust collector without explosion controls. An ember from the misaligned sanding belt was transported into the dust collection conveyance conduit to the separation cyclone, exposing a dispersed fraction of combustible aluminum dust to a source of ignition. A super-heated percussion wave pushed backwards through the dust collection conveyance ducting from the dust collection separator, and hit the 15 proximally-located employees with super-heated air causing second degree burns and a percussion wave that caused Barotrauma effects to the brain and Eustachian tubes and loss of hearing. Employee #1 was hospitalized for his injuries. injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR GENERAL DUTY CLAUSE |
Unclassified | $12,675 | $7,605 | Apr 2, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.1200(h)(3) · Hazard communication |
Other-than-serious | $12,675 | $7,605 | Apr 2, 2018 | Final |
Panton Road, Vergennes, VT 05491 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.108(b)(1) · [Reserved] |
Serious | $240 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 1b 29 CFR 1910.108(c)(5) · [Reserved] |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 1c 29 CFR 1910.108(d) · [Reserved] |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 1d 29 CFR 1910.108(e)(1)(i) · [Reserved] |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 1e 29 CFR 1910.108(e)(2) · [Reserved] |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 1f 29 CFR 1910.108(f)(2) · [Reserved] |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 2a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $300 | $300 | Jan 22, 1986 | Closed |
| Citation 1, item 2b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 1, item 3a 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $360 | $360 | Jan 22, 1986 | Closed |
| Citation 1, item 3b 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 2 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 3 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 4 29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 5 29 CFR 1910.24(i) · Fixed industrial stairs |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 6 29 CFR 1910.36(d)(2) · Exit route design |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 7 29 CFR 1910.37(g)(2) · Exit routes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 8 29 CFR 1910.37(f)(6) · Exit routes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 9 29 CFR 1910.37(q)(1) · Exit routes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 10 29 CFR 1910.106(e)(2)(iib) · Flammable liquids |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 11 29 CFR 1910.106(e)(6)(i) · Flammable liquids |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 12 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 13 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 14 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 15 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 16 29 CFR 1910.110(d)(10) · Storage and handling of liquefied petroleum gases |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 17a 29 CFR 1910.133(a)(1) · Eye and face protection |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 17b 29 CFR 1910.133(a)(1) · Eye and face protection |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 18 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 19 29 CFR 1910.151(c) · First aid and eyewash |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 20 29 CFR 1910.157(d)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 21 29 CFR 1910.157(d)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 22 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 23 29 CFR 1910.179(b)(5) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 24 29 CFR 1910.179(g)(1)(iv) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 25 29 CFR 1910.179(j)(3) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 26 29 CFR 1910.184(i)(1) · Slings |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 27 29 CFR 1910.212(a)(1)(0) · Machine guarding |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 28 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 29 29 CFR 1910.212(a)(5) · Machine guarding |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 30 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 31 29 CFR 1910.213(c)(3) · Woodworking machinery |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 32 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 33 29 CFR 1910.252(a)(2)(ivc) · Welding fire safety |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 34 29 CFR 1910.252(b)(4)(ixc) · Welding fire safety |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 35 29 CFR 1910.252(e)(4)(v) · Welding fire safety |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 36 29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 37 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 38 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 39 29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 40 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 41 29 CFR 1910.305(g)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 42 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 43 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 44 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 45 29 CFR 1910.305(i)(2)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
| Citation 2, item 46 29 CFR 1910.305(j)(3)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 22, 1986 | Closed |
Exchange St, Middlebury, VT 05753 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(4)(iii) · Flammable liquids |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 2 29 CFR 1910.106(e)(2)(iii) · Flammable liquids |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 3 29 CFR 1910.106(e)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 4 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 5 29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
| Citation 1, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 9, 1983 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Vergennes site logged 4 recordable injuries or illnesses among about 679 workers: 0.6 per 100 full-time workers, against a median of 0.3 for its industry. Those cases cost 68 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Simmonds Precision Products Inc. Vergennes · 2025 | 679 | 4 | 1 | 0.6 | 0.3 |
| Simmonds Precision Products Inc Vergennes · 2024 | 947 | 6 | 1 | 0.6 | 1.1 |
| Simmonds Precision Products, Inc. Vergennes · 2022 | 988 | 3 | 1 | 0.3 | 1.1 |
| Simmonds Precision Products Inc Vergennes · 2022 | 988 | 3 | 1 | 0.3 | 1.1 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.106(e)(2)(iib)
(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.
29 CFR 1910.106(e)(2)(iii)
(iii) Separation and protection. Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided.
Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.