OSHA SearchOSHA records by employer

Smith Masonry: OSHA inspections and violations

Bloomington, Indiana · Masonry Contractors · NAICS 238140

1inspections
3citation items
$584current penalties
Aug 17, 2020last inspection

OSHA has inspected Smith Masonry once in Indiana.

The inspection began on Aug 17, 2020 on a referral, in Bloomington.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $900 and now stand at $584, 35% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Smith Masonry averages $584 (1 cited inspection).

Smith Masonry: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Smith Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344884234 OPENED AUG 17, 2020Closed

Referral · Partial · Safety · 4 employees at the site · Closed Oct 27, 2020

410 N Gates Dr, Bloomington, IN 47404 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$292Oct 13, 2020Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$450$292Oct 13, 2020Final
Citation 2, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Oct 13, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

Other masonry contractors employers in Indiana

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.