OSHA SearchOSHA records by employer

Solar Roof Solutions Inc.: OSHA inspections and violations

Clearwater, Florida · Roofing Contractors · NAICS 238160

5inspections
11citation items
$43,165current penalties
Jan 25, 2018last inspection

OSHA has inspected Solar Roof Solutions Inc. 5 times in Florida since 2013.

The latest one began on Jan 25, 2018 as a planned inspection, in Sarasota.

Those inspections ended with 11 citation items: 7 serious, 3 repeat and 1 other-than-serious.

Penalties were first proposed at $69,995 and now stand at $43,165, 38% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 5 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Solar Roof Solutions Inc. averages $11,788 (3 cited inspections).

Solar Roof Solutions Inc.: OSHA citation items per year, 2013 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Solar Roof Solutions Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342905536 OPENED JAN 25, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 7, 2018

2113 Reynolds Street, Sarasota, FL 34231 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$21,341$10,670Apr 16, 2018Final

Inspection 342779501 OPENED NOV 16, 2017Closed

Planned · Partial · Safety · 21 employees at the site · Closed Aug 3, 2018

Palmera Pointe Condominiums 7417 Palmera Pointe Cir, Tampa, FL 33615 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,439$1,462Jan 8, 2018Final
Citation 1, item 1b
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$0$0Jan 8, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$28,455$17,073Jan 8, 2018Final
Citation 3, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jan 8, 2018Final

Inspection 341556991 OPENED JUN 15, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 18, 2016

1500 Seagull Drive, Palm Harbor, FL 34685 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$6,160$6,160Jul 15, 2016Final

Inspection 339561508 OPENED JAN 24, 2014Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 8, 2014

113 N Betty Lan, Clearwater, FL 33756 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,800$1,400Jan 31, 2014Final
Citation 1, item 2
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$2,000$1,000Jan 31, 2014Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,800$1,400Jan 31, 2014Final

Inspection 338726037 OPENED FEB 7, 2013Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 18, 2014

113 N. Betty Lane, Clearwater, FL 33755 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000Feb 13, 2013Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$2,000Feb 13, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.