Inspection 340427228 OPENED FEB 25, 2015Closed
7263 Main St, Ovid, NY 14521 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
South Seneca CSD High School has 11 OSHA inspections on record in New York, the first in 1988.
OSHA's last visit started on Feb 25, 2015 to follow up on an earlier case, in Ovid.
Across those inspections OSHA issued 77 citation items: 64 serious and 13 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.305, electrical wiring methods (7 items).
For context, across all education employers the median penalty per cited inspection since 2015 is $0. South Seneca CSD High School averages $0 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
361employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch South Seneca CSD High School and get notified the morning OSHA posts a new citation for it.
Watch this company7263 Main St, Ovid, NY 14521 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7263 Main St, Ovid, NY 14521 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.179(b)(3) · Overhead and gantry cranes |
Serious | $0 | $0 | Feb 4, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Feb 4, 2015 | Final |
| Citation 2, item 1 29 CFR 1904.31(a) · Covered employees |
Other-than-serious | $0 | $0 | Feb 4, 2015 | Final |
7263 Main St, Ovid, NY 14521 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7263 Main St, Ovid, NY 14521 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 2 29 CFR 1910.213(d)(1) · Woodworking machinery |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 3 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 4 29 CFR 1910.244(a)(2)(via) · Other portable tools and equipment |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 5 29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 6 29 CFR 1910.305(d)(2) · Electrical wiring methods |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
| Citation 1, item 7 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Oct 28, 2010 | Closed |
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(2) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Jan 19, 1994 | Closed |
| Citation 1, item 2 29 CFR 1910.1030(c)(1)(iib) · Bloodborne pathogens |
Serious | $0 | $0 | Jan 19, 1994 | Closed |
| Citation 2, item 1 29 CFR 1910.1030(d)(4)(iiib)(1) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Jan 19, 1994 | Closed |
| Citation 2, item 2 29 CFR 1910.1030(f)(2)(iv) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Jan 19, 1994 | Closed |
| Citation 2, item 3 29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories |
Other-than-serious | $0 | $0 | Jan 19, 1994 | Closed |
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 2 29 CFR 1910.36(d)(1) · Exit route design |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 3 29 CFR 1910.133(a)(1) · Eye and face protection |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 4 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 5 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 6 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 7 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
| Citation 2, item 8 29 CFR 1910.305(g)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 2 29 CFR 1910.24(h) · Fixed industrial stairs |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 3 29 CFR 1910.25(d)(1) · Portable wood ladders |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 4 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 5 29 CFR 1910.37(q)(1) · Exit routes |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 6 29 CFR 1910.106(d)(3)(ii) · Flammable liquids |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 7 29 CFR 1910.106(f)(6) · Flammable liquids |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 8 29 CFR 1910.106(g)(3)(iii) · Flammable liquids |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 9 29 CFR 1910.108(f)(4) · [Reserved] |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 10 29 CFR 1910.145(c)(5) · Specifications for accident prevention signs and tags |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 11 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 12 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 13 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 14 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 15 29 CFR 1910.242(b) · Hand and power tools |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 16 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 17 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 18 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 19 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 20 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 21 29 CFR 1910.304(f)(7)(iii) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 22 29 CFR 1910.305(a)(2)(iiif) · Electrical wiring methods |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 23 29 CFR 1910.305(e)(2) · Electrical wiring methods |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 24 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
| Citation 1, item 25 29 CFR 1910.110(h)(12) · Storage and handling of liquefied petroleum gases |
Serious | $0 | $0 | Apr 15, 1988 | Closed |
7263 Main St, Ovid, NY 14521 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(2) · General requirements |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 2 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 3 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 4 29 CFR 1910.37(k)(2) · Exit routes |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 5 29 CFR 1910.37(b)(1) · Exit routes |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 6 29 CFR 1910.37(q)(1) · Exit routes |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 7 29 CFR 1910.37(q)(1) · Exit routes |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 8 29 CFR 1910.106(b)(1) · Flammable liquids |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 9 29 CFR 1910.106(d)(3)(ii) · Flammable liquids |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 10 29 CFR 1910.108(b)(1) · [Reserved] |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 11 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 12 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 13 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 14 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 15 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 16 29 CFR 1910.213(b)(3) · Woodworking machinery |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 17 29 CFR 1910.213(a)(6) · Woodworking machinery |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 18 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 19 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 20 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 21 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 22 29 CFR 1910.242(b) · Hand and power tools |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 23 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 24 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 25 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 26 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 1, item 27 29 CFR 1910.304(f)(7)(iii) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 5, 1988 | Closed |
| Citation 2, item 1 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 5, 1988 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.31(a)
(a) Basic requirement. You must record on the OSHA 300 Log the recordable injuries and illnesses of all employees on your payroll, whether they are labor, executive, hourly, salary, part-time, seasonal, or migrant workers. You also must record the recordable injuries and illnesses that occur to employees who are not on your payroll if you supervise these employees on a day-to-day basis. If your business is organized as a sole proprietorship or partnership, the owner or partners are not considered employees for recordkeeping purposes.
29 CFR 1910.1030(c)(1)(iib)
(B) The schedule and method of implementation for paragraphs (d) Methods of Compliance, (e) HIV and HBV Research Laboratories and Production Facilities, (f) Hepatitis B Vaccination and Post-Exposure Evaluation and Follow-up, (g) Communication of Hazards to Employees, and (h) Recordkeeping, of this standard, and
29 CFR 1910.1030(d)(4)(iiib)(1)
(B) Other Regulated Waste Containment—(1) Regulated waste shall be placed in containers which are:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.