OSHA SearchOSHA records by employer

Southeastern Contractors Company, LLC: OSHA inspections and violations

Raleigh, North Carolina · Roofing Contractors · NAICS 238160

2inspections
6citation items
$3,300current penalties
Aug 9, 2017last inspection

Southeastern Contractors Company, LLC has 2 OSHA inspections on record in North Carolina, the first in 2015.

OSHA's last visit started on Aug 9, 2017, in Wake Forest.

Across those inspections OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

OSHA proposed $3,300 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.502, fall protection systems (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Southeastern Contractors Company, LLC averages $1,650 over 2 cited inspections in that time.

Southeastern Contractors Company, LLC: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

19 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Southeastern Contractors Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342534286 OPENED AUG 9, 2017Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Jan 24, 2018

1200 Debarmore Street, Wake Forest, NC 27587 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,000$2,000Sep 26, 2017Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$400$400Sep 26, 2017Final
Citation 2, item 2
29 CFR 1926.502(d)(21) · Fall protection systems
Other-than-serious$0$0Sep 26, 2017Final

Inspection 317989085 OPENED MAY 28, 2015Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Dec 10, 2015

1321 Oberlin Road, Raleigh, NC 27605 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$900$900Jun 23, 2015Closed
Citation 1, item 1b
29 CFR 1926.502(k)(3) · Fall protection systems
Serious$0$0Jun 23, 2015Closed
Citation 1, item 1c
29 CFR 1926.502(h)(1)(v) · Fall protection systems
Serious$0$0Jun 23, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.