OSHA SearchOSHA records by employer

Southern Cast, Inc.: OSHA inspections and violations

Charlotte, North Carolina · Iron Foundries · NAICS 331511

5inspections
36citation items
$2,900current penalties
May 29, 2019last inspection

Southern Cast, Inc. has 5 OSHA inspections on record in North Carolina, the first in 2001.

OSHA's last visit started on May 29, 2019 as a planned inspection, in Charlotte.

Across those inspections OSHA issued 36 citation items: 19 serious and 17 other-than-serious.

OSHA proposed $3,400 in penalties. After settlements and reviews the total is $2,900, down 15%.

Most often, OSHA cited 1910.147, lockout/tagout (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Southern Cast, Inc. averages $1,500 over 1 cited inspection in that time.

Southern Cast, Inc. also files yearly injury logs with OSHA, summarized below.

Southern Cast, Inc.: OSHA citation items per year, 2001 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Southern Cast, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344044037 OPENED MAY 29, 2019Closed

Planned · Complete · Safety · 25 employees at the site · Closed Nov 8, 2019

901 North Church Street, Charlotte, NC 28206 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,000$750Jul 5, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,000$750Jul 5, 2019Final

Inspection 317716546 OPENED MAY 28, 2014Closed

Referral · Partial · Safety · 23 employees at the site · Closed Sep 15, 2014

901 North Church Street, Charlotte, NC 28206 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$300$300Aug 26, 2014Closed

Inspection 313423238 OPENED MAY 19, 2009Closed

Planned · Complete · Health · 17 employees at the site · Closed Jul 21, 2009

901 N Church St, Charlotte, NC 28206 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$250$250Jul 2, 2009Closed
Citation 1, item 1b Serious$0$0Jul 2, 2009Closed
Citation 1, item 2 Serious$150$150Jul 2, 2009Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 2, 2009Closed
Citation 2, item 2
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jul 2, 2009Closed
Citation 2, item 3
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jul 2, 2009Closed

Inspection 306842980 OPENED JUN 5, 2003Closed

Planned · Partial · Health · 23 employees at the site · Closed Sep 2, 2003

901 N. Church St, Charlotte, NC 28206 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1000(c) · Air contaminants
Serious$200$200Jul 24, 2003Closed
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jul 24, 2003Closed
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Jul 24, 2003Closed
Citation 2, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jul 24, 2003Closed

Inspection 304622939 OPENED JUN 20, 2001Closed

Planned · Complete · Health · 19 employees at the site · Closed Sep 28, 2001

901 N. Church St, Charlotte, NC 28206 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$100$100Aug 22, 2001Closed
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Aug 22, 2001Closed
Citation 1, item 1c
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Aug 22, 2001Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$100$100Aug 22, 2001Closed
Citation 1, item 3a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$100$100Aug 22, 2001Closed
Citation 1, item 3b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Aug 22, 2001Closed
Citation 1, item 3c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Aug 22, 2001Closed
Citation 1, item 4a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$100$100Aug 22, 2001Closed
Citation 1, item 4b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Aug 22, 2001Closed
Citation 1, item 5a
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$100$100Aug 22, 2001Closed
Citation 1, item 5b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 22, 2001Closed
Citation 1, item 5c
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$0$0Aug 22, 2001Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 2
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 3
29 CFR 1910.37(f)(6) · Exit routes
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 4
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 5
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 6 Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 7
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 8
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 9
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 2001Closed
Citation 2, item 11 Other-than-serious$0$0Aug 22, 2001Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Charlotte site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 5.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Southern Cast Inc.
Charlotte · 2024
20 000.05.4

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other iron foundries employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.