OSHA SearchOSHA records by employer

Spartan Light Metal Products, Inc.: OSHA inspections and violations

Sparta, Illinois · Nonferrous Metal Foundries · NAICS 331521

6inspections
12citation items
$27,580current penalties
Jan 30, 2024last inspection

Spartan Light Metal Products, Inc. has 6 OSHA inspections on record in Illinois, the first in 2006.

OSHA's last visit started on Jan 30, 2024 after a complaint, in Sparta.

Across those inspections OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

OSHA proposed $59,995 in penalties. After settlements and reviews the total is $27,580, down 54%.

Most often, OSHA cited 1910.147, lockout/tagout (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Spartan Light Metal Products, Inc. averages $4,585 over 3 cited inspections in that time.

Spartan Light Metal Products, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Spartan Light Metal Products, Inc.: OSHA citation items per year, 2006 to 2024
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Spartan Light Metal Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347242893 OPENED JAN 30, 2024Closed

Complaint · Partial · Safety · 412 employees at the site · Closed Aug 13, 2024

510 East Mcclurken Avenue, Sparta, IL 62286 · Nonferrous Metal Die-Casting Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$6,913$4,493May 16, 2024Final
Citation 1, item 2
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$11,524$5,762May 16, 2024Final

Inspection 345060198 OPENED DEC 10, 2020Closed

Referral · Partial · Safety · 393 employees at the site · Closed Sep 23, 2021

510 East Mcclurken Avenue, Sparta, IL 62286 · Nonferrous Metal Die-Casting Foundries · OSHA's record · Phone and website on Google Maps

Incident on Dec 4, 2020: Three of employee's fingers are crushed and later amputated

At about 10:00 p.m. on December 4, 2020, an employee was working for a nonferrous metal diecasting foundry. He was a machine operator. He was in the operations part of the facility. He and a coworker were changing mold plates on the B�hlerPrince DCM065 cell number 56 1400TT Cc diecast machine. Power to the machine had been shut off at the electrical disconnect. As the two were connecting hydraulic lines, they ran into complications. They couldn't make a connection, so they tried clearing debris from the hydraulic line quick connect couplers. They continued to experience issues. Their next step was relieving pressure on the lines by draining hydraulic fluid that was pressurizing the machine. At approximately 10:30 p.m., the coworker went to manually drain hydraulic fluid from the machine's accumulators. As the coworker performed this operation, the employee placed his left hand inside and on the edge of a locking-pin hole on one of the mold plates. He did this to maintain his balance while he used a tool to break the hydraulic line with the malfunctioning connector loose from the machine. When the employee removed the hydraulic line from the machine, the pressure that was holding the mold's slide core in an elevated position fell. The slide core as well dropped and closed, and the small, ring, and index fingers of the employee's left hand were crushed. The employee was taken to a major hospital in St Louis MO. He was hospitalized. His three crushed fingers were surgically amputated. Established lockout/tagout procedures were not followed for performing service on the machine. The release of the stored pressure caused the employee to be exposed to movement of the slide core.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0May 5, 2021Final

Inspection 340835495 OPENED AUG 7, 2015Closed

Referral · Partial · Safety · 600 employees at the site · Closed Dec 28, 2016

510 East Mcclurken Avenue, Sparta, IL 62286 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(d) · Lockout/tagout
Serious$7,000$3,500Feb 3, 2016Final

Inspection 334601150 OPENED JUN 7, 2012Closed

Complaint · Partial · Safety · 400 employees at the site · Closed Feb 15, 2013

510 East Mcclurken Avenue, Sparta, IL 62286 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,250$4,250Nov 7, 2012Final

Inspection 309286227 OPENED SEP 18, 2006Closed

Complaint · Partial · Safety · 567 employees at the site · Closed Dec 5, 2007

510 East Mcclurken Avenue, Sparta, IL 62286 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,975$2,000Dec 12, 2006Closed
Citation 1, item 2
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Serious$1,083$700Dec 12, 2006Closed
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$17,500$2,500Dec 12, 2006Final

Inspection 309284321 OPENED MAR 8, 2006Closed

Complaint · Partial · Safety · 567 employees at the site · Closed Jun 26, 2006

510 East Mcclurken Avenue, Sparta, IL 62286 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,500$2,250May 10, 2006Closed
Citation 1, item 2
29 CFR 1910.212(a)(2) · Machine guarding
Serious$2,250$1,125May 10, 2006Closed
Citation 1, item 3
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$2,000$1,000May 10, 2006Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 10, 2006Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Sparta site logged 15 recordable injuries or illnesses among about 392 workers: 3.6 per 100 full-time workers, against a median of 5.4 for its industry. Those cases cost 2 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Spartan Light Metal Products
Sparta · 2023
392 1523.65.4
Sparta location
Sparta · 2022
434 1213.55.4

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Dec 4, 2020, Sparta: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was attempting to bleed off a hydraulic cylinder on a diecast mold. Their hand was placed on the side where the hydraulic cylinder was hooked to when it lowered and amputated three fingers.

Aug 4, 2015, Sparta: Hospitalization · heat (thermal) burns, unspecified · back, including spine, spinal cord, unspecified

A metal ladle struck an employee in the back, resulting in burns. An interlock failed and the employee was not protected at the time.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other nonferrous metal foundries employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.