OSHA has inspected Spendless Building Supplies, Inc. once in Florida.

The inspection began on Apr 30, 2021 after a complaint, in Tampa.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $10,533 and now stand at $6,320, 40% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 2 items under 1910.219.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Spendless Building Supplies, Inc. averages $6,320 (1 cited inspection).

Spendless Building Supplies, Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Spendless Building Supplies, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345294524 OPENED APR 30, 2021Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jun 2, 2022

12200 N Nebraska Ave, Tampa, FL 33612 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,341$1,405Oct 26, 2021Final
Citation 1, item 2
29 CFR 1910.213(a)(12) · Woodworking machinery
Serious$1,755$1,053Oct 26, 2021Final
Citation 1, item 3
29 CFR 1910.213(n)(3) · Woodworking machinery
Serious$2,341$1,405Oct 26, 2021Final
Citation 1, item 4
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$1,755$1,053Oct 26, 2021Final
Citation 1, item 5
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$2,341$1,405Oct 26, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(a)(12)

(12) For all circular saws where conditions are such that there is a possibility of contact with the portion of the saw either beneath or behind the table, that portion of the saw shall be covered with an exhaust hood, or, if no exhaust system is required, with a guard that shall be so arranged as to prevent accidental contact with the saw.

29 CFR 1910.213(n)(3)

(3) Feed rolls shall be guarded by a hood or suitable guard to prevent the hands of the operator from coming in contact with the in-running rolls at any point. The guard shall be fastened to the frame carrying the rolls so as to remain in adjustment for any thickness of stock.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(e)(3)(i)

(3) Vertical and inclined belts. (i) Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.

OSH Act Section 5 · General Duty Clause

Other other building material dealers employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.