Inspection 345184774 OPENED MAR 9, 2021Closed
Pyles Pad 509 Nash Run Rd, Middlebourne, WV 26149 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
Incident on Mar 7, 2021: Employee receives burns from ignited flammable vapors
At 8:45 a.m. on March 7, 2021, Employee #1 was performing maintenance on a Gas Production Unit when he opened a valve to allow the unit to bleed off. Fluid began coming out of the valve, and the flammable vapors were ignited by a nearby pilot light. The employee, who was in the vicinity of the ignited vapors, sustained burns to the hands, face, and back. Emergency services were called, and the employee was transported to the hospital for admission and treatment.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $13,653 | $9,557 | Jul 1, 2021 | Final |