Sta-Bilt Construction Company: OSHA inspections and violations
Harlan, Iowa · Highway, Street, and Bridge Construction · NAICS 237310
2inspections
5citation items
$5,540current penalties
May 13, 2022last inspection
Sta-Bilt Construction Company has 2 OSHA inspections on record in Iowa, the first in 2019.
OSHA's last visit started on May 13, 2022 after a fatality or catastrophe, in Red Oak.
Across those inspections OSHA issued 5 citation items: 5 serious.
OSHA proposed $5,540 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.333, working near live electrical parts (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sta-Bilt Construction Company averages $5,540 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Sta-Bilt Construction Company also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Iowa · latest 90 days of OSHA records
67employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Sta-Bilt Construction Company and get notified the morning OSHA posts a new citation for it.
Incident on May 12, 2022 (fatal): Employee is killed when struck by vehicle
At 6:45 p.m. on May 12, 2022, an employee was working as a flagger for road construction and waterproofing on a highway. The highway was restricted to one-way with a pilot car to guide traffic past the construction work zone. While the employee was standing with their stop/slow sign in the stop position, a vehicle did not stop and struck the employee. The employee was killed when struck by the vehicle.
No citations from this inspection.
Inspection 343962270 OPENED APR 26, 2019Closed
Referral · Partial · Safety · 7 employees at the site · Closed Jun 4, 2019
Incident on Apr 23, 2019: Employee's hands are burned in arc flash
At 7:45 a.m. on April 23, 2019, Employee #1, employed by a highway construction company, was using an Extech 430 Multi Meter to perform a diagnostic test on a 480 volt 50 amp circuit ITE circuit breaker that was not functioning in an emulsion tank electrical panel. When the employee touched the positive and negative test leads of the meter to the power supply side of the circuit breaker, an arc flash occurred. The arc flash burned the test leads of the meter and the tops of multiple fingers on the employee's hands. The employee, who had not been wearing personal protective equipment, was transported to the hospital, where he was admitted for treatment of the burns.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Harlan site logged 0 recordable injuries or illnesses among about 29 workers: 0.0 per 100 full-time workers, against a median of 2.2 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Sta-Bilt
Harlan · 2025
29
0
0
0.0
2.2
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.219 · Belts, pulleys and power-transmission parts
29 CFR 1910.219(d)(1)
(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.
29 CFR 1910.219(e)(1)(i)
(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.