OSHA SearchOSHA records by employer

Staley Electric Services, LLC: OSHA inspections and violations

Little Rock, Arkansas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
1citation items
$65,000current penalties
Oct 6, 2021last inspection

OSHA has inspected Staley Electric Services, LLC once in Arkansas.

The inspection began on Oct 6, 2021 after a fatality or catastrophe, in Little Rock.

That inspection ended with 1 citation item: 1 repeat.

Penalties were first proposed at $116,022 and now stand at $65,000, 44% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Staley Electric Services, LLC averages $65,000 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Staley Electric Services, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Staley Electric Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345567002 OPENED OCT 6, 2021Closed

Fatality or catastrophe · Partial · Safety · 70 employees at the site · Closed Mar 22, 2024

17500 Cantrell Rd, Little Rock, AR 72223 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 6, 2021 (fatal): Employee is electrocuted and killed while installing light f

At 7:00 a.m. on October 6, 2021, an employee installed light fixtures and was in the process of assembling a terminal to an electrical circuit. While working, a coworker turned on the circuit breaker to the circuit the employee was working on. The employee received a 277-volt electric shock and fell from an eight-foot ladder. The employee was killed by electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Repeat$116,022$65,000Feb 22, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

Other electrical contractors and other wiring installation contractors employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.