OSHA SearchOSHA records by employer

Standard Utility Construction, Inc.: OSHA inspections and violations

Fort Worth, Texas · All Other Support Services · NAICS 561990

2inspections
3citation items
$12,675current penalties
Mar 19, 2019last inspection

Standard Utility Construction, Inc. has 2 OSHA inspections on record in Texas, the first in 2017.

OSHA's last visit started on Mar 19, 2019 on a referral, in Sachse.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $34,404 in penalties. After settlements and reviews the total is $12,675, down 63%.

Most often, OSHA cited 1910.335, safeguards for personnel protection (2 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Standard Utility Construction, Inc. averages $12,675 over 1 cited inspection in that time.

Standard Utility Construction, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Standard Utility Construction, Inc.: OSHA citation items per year, 2017 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Standard Utility Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343863890 OPENED MAR 19, 2019Closed

Referral · Partial · Safety · 330 employees at the site · Closed Jun 11, 2019

2404 Acorn Ct., Sachse, TX 75048 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 12, 2019: Employee installing electrical wire in pedestal is shocked

At 4:45 p.m. on March 12, 2019, Employee #1, employed by a power line construction company, was working at the site of a new residential townhouse. He was installing wire inside a pedestal when he came into contact with the pedestal busbar that distributed power to the townhouse. The busbar was live/energized. The employee, who was wearing flame resistant clothing and electrical rated gloves, sustained an electric shock. He was transported by emergency services to the hospital, where he was admitted for treatment of electric shock.

No citations from this inspection.

Inspection 342023983 OPENED JAN 12, 2017Closed

Referral · Partial · Safety · 324 employees at the site · Closed May 3, 2017

4801 City Lake Blvd. East, Fort Worth, TX 76132 · All Other Support Services · OSHA's record · Phone and website on Google Maps

Incident on Jan 10, 2017: Utility worker searching for underground conduit is electroc

At 10:00 a.m. on January 10, 2017, Employee #1, employed by a utility construction company, was attempting to locate an underground conduit. He was using a fiberglass duct rod with an attached copper wire. The rod came into contact with a ground bar inside an energized switch gear. Employee #1 received an electrical shock. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for the electrical shock and burns to his shoulder and both feet.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$9,054$12,675Apr 19, 2017Final
Citation 1, item 1b
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$12,675$0Apr 19, 2017Final
Citation 1, item 1c
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$12,675$0Apr 19, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Fort Worth site logged 9 recordable injuries or illnesses among about 70 workers: 9.7 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 30 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
DMS - Fort Worth
Fort Worth · 2025
70 939.71.0
Standard Utility Construction, Inc. - Corporate
Fort Worth · 2025
24 000.00.0
DMS
Fort Worth · 2023
58 304.11.0
CS
Fort Worth · 2022
48 9013.81.0
Organizaiton
Fort Worth · 2021
365 3467.81.0
Fort Worth/183
Fort Worth · 2018
44 8214.21.0
Forest Park
Fort Worth · 2018
21 000.01.0

Included with any plan: 11 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Jul 23, 2020, Fort Worth: Hospitalization · multiple effects of heat and light · body systems

Within 15 minutes of being on the job, an employee became ill. He continued to work throughout the day, taking frequent rest breaks. The employee was having cramps on his left side throughout the day. After finishing the day, the employee went home and was later hospitalized with dehydration, suspected heat exhaustion, and acute kidney failure.

Mar 12, 2019, Sachse: Hospitalization · electrocutions, electric shocks · body systems

An employee was installing new wire during construction of a residential townhome and contacted a live pedestal buss bar resulting in electrocution. The employee was wearing flame resistant clothing and electrical protector gloves at the time.

Nov 2, 2018, Fort Worth: Hospitalization · herniated discs · back, including spine, spinal cord, unspecified

An employee slipped on uneven terrain and fell to the ground. The employee suffered bulging discs.

Jan 10, 2017, Fort Worth: Hospitalization · electrical burns, unspecified · multiple body parts, n.e.c.

An employee was attempting to locate an underground conduit by using a fiberglass duct rod with an attached copper wire. The rod came into contact with a ground bar inside a switch gear, causing an electric shock that burned the employee's shoulder and both feet.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(1)

(b) Content of training—(1) Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by §§ 1910.331 through 1910.335 that pertain to their respective job assignments.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.335(a)(1)(i)

(a) Use of protective equipment—(1) Personal protective equipment. (i) Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.

29 CFR 1910.335(a)(2)(i)

(2) General protective equipment and tools. (i) When working near exposed energized conductors or circuit parts, each employee shall use insulated tools or handling equipment if the tools or handling equipment might make contact with such conductors or parts. If the insulating capability of insulated tools or handling equipment is subject to damage, the insulating material shall be protected.

Other all other support services employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.