OSHA SearchOSHA records by employer

Steel Building Erectors, Inc.: OSHA inspections and violations

Braselton, Georgia · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
7citation items
$6,594current penalties
Oct 6, 2016last inspection

Steel Building Erectors, Inc. has 5 OSHA inspections on record in Georgia, the first in 2002.

OSHA's last visit started on Oct 6, 2016 as a planned inspection, in Cornelia.

Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

OSHA proposed $7,540 in penalties. After settlements and reviews the total is $6,594, down 13%.

Most often, OSHA cited 1926.760, fall protection (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Steel Building Erectors, Inc. averages $1,722 over 2 cited inspections in that time.

Steel Building Erectors, Inc.: OSHA citation items per year, 2002 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Steel Building Erectors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341822534 OPENED OCT 6, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 2, 2017

1725 U.s Hwy 441, Cornelia, GA 30531 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,940$1,764Nov 18, 2016Final

Inspection 341377976 OPENED APR 5, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 8, 2016

2896 Browns Bridge Road, Gainesville, GA 30507 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,800$1,680Apr 22, 2016Final

Inspection 315738047 OPENED AUG 24, 2011Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 3, 2012

1210 Hulsey Rd, Cleveland, GA 30528 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$2,400Oct 4, 2011Closed
Citation 1, item 3b
29 CFR 1926.760(a)(1) · Fall protection
Serious$0$0Oct 4, 2011Closed

Inspection 314093493 OPENED MAY 5, 2011Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Mar 28, 2012

301 Aj Riggs Road, Statesboro, GA 30458 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304631377 OPENED JUN 20, 2002Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Oct 19, 2002

1945 Braselton Hwy, Braselton, GA 30517 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,500$750Sep 27, 2002Closed
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Sep 27, 2002Closed
Citation 1, item 2
29 CFR 1926.602(c)(1)(vii) · Earthmovers and forklifts in construction
Other-than-serious$300$0Sep 27, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.760 · Fall protection

OSH Act Section 5 · General Duty Clause

Other structural steel and precast concrete contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.