OSHA SearchOSHA records by employer

Stever's Roof Side Remodel, Ltd: OSHA inspections and violations

Toledo, Ohio · Roofing Contractors · NAICS 238160

4inspections
8citation items
$8,158current penalties
Jun 18, 2020last inspection

OSHA has inspected Stever's Roof Side Remodel, Ltd 4 times in Ohio since 2008.

The latest one began on Jun 18, 2020 on a referral, in Oregon.

Those inspections ended with 8 citation items: 6 serious, 1 repeat and 1 other-than-serious.

Penalties were first proposed at $15,428 and now stand at $8,158, 47% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Stever's Roof Side Remodel, Ltd averages $2,458 (1 cited inspection).

Stever's Roof Side Remodel, Ltd: OSHA citation items per year, 2008 to 2020
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

65 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Stever's Roof Side Remodel, Ltd and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344794995 OPENED JUN 18, 2020Closed

Referral · Complete · Safety · 6 employees at the site · Closed May 2, 2023

5475 Bay Shore Road, Oregon, OH 43616 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,458$2,458Aug 26, 2020Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Aug 26, 2020Final

Inspection 337368625 OPENED NOV 14, 2012Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 20, 2019

4630 Curtis Road, Northwood, OH 43619 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$3,520$2,000Dec 4, 2012Final

Inspection 313785446 OPENED OCT 28, 2010Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jun 9, 2014

3121 Glanzman Rd., Toledo, OH 43614 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(h)(1)(v) · Fall protection systems
Serious$3,300$1,200Nov 18, 2010Closed

Inspection 311602841 OPENED APR 8, 2008Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 1, 2014

2600 Copeland Blvd., Toledo, OH 43605 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$200May 5, 2008Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,100$850May 5, 2008Closed
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,100$850May 5, 2008Closed
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$600May 5, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.