OSHA SearchOSHA records by employer

Steves & Sons, Inc.: OSHA inspections and violations

Sandston, Virginia · Wood Window and Door Manufacturing · NAICS 321911

9inspections
115citation items
$53,798current penalties
Jan 13, 2026last inspection

Since 1989, OSHA inspectors have visited Steves & Sons, Inc. in Virginia 9 times.

The most recent inspection opened on Jan 13, 2026 after an accident, in Sandston and is still open.

In all, OSHA issued 115 citation items: 82 serious and 33 other-than-serious.

The proposed penalties came to $63,280; today they stand at $53,798, 15% less.

The rule cited most here is 1910.305 (electrical wiring methods), 15 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Steves & Sons, Inc. averages $13,459 across 3 cited inspections.

Steves & Sons, Inc. also files yearly injury logs with OSHA, summarized below.

Steves & Sons, Inc.: OSHA citation items per year, 1989 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Steves & Sons, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Steves & Sons, Inc. at 3 sites in 3 states. Together they've had 29 inspections and $124,616 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 348683046 OPENED JAN 13, 2026Open

Accident · Partial · Safety · 143 employees at the site · Open

5640 Lewis Road, Sandston, VA 23150 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$16,285$16,285Feb 10, 2026Contested
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$16,285$16,285Feb 10, 2026Contested

Inspection 345599989 OPENED OCT 26, 2021Closed

Complaint · Partial · Safety · 140 employees at the site · Closed Dec 21, 2021

5640 Lewis Rd., Sandston, VA 23150 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Nov 22, 2021Final
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 22, 2021Final

Inspection 343532800 OPENED OCT 15, 2018Closed

Referral · Partial · Safety · 180 employees at the site · Closed Feb 6, 2019

5640 Lewis Road, Sandston, VA 23150 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 8, 2018: Employee amputates two fingertips on router

At 4:23 p.m. on October 8, 2018, Employee #1 was attempting to work on a router. He did not lockout the machine. The employee put his fingers on the moving router blade, resulting in the amputation of two fingertips.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$9,760$7,808Dec 26, 2018Final
Citation 1, item 1b
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0Dec 26, 2018Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Other-than-serious$0$0Dec 26, 2018Final

Inspection 311443238 OPENED SEP 7, 2007Closed

Planned · Partial · Safety · 104 employees at the site · Closed Sep 12, 2007

5325 Glen Alden Road, Sandston, VA 23231 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304777212 OPENED MAY 16, 2002Closed

Planned · No inspection · Safety · 150 employees at the site · Closed May 16, 2002

5325 Glen Alden Road, Sandston, VA 23231 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125460329 OPENED NOV 22, 1994Closed

Planned · Complete · Safety · 65 employees at the site · Closed Aug 15, 1995

5325 Glen Alden Road, Sandston, VA 23231 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 510001 A
Serious$875$583Jan 27, 1995Final
Citation 1, item 2
29 CFR 1910.22(a)(1) · General requirements
Serious$875$583Jan 27, 1995Final
Citation 1, item 3
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Serious$525$350Jan 27, 1995Final
Citation 1, item 4a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$700$467Jan 27, 1995Final
Citation 1, item 4b
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$0$0Jan 27, 1995Final
Citation 1, item 4c
29 CFR 1910.24(e) · Fixed industrial stairs
Serious$0$0Jan 27, 1995Final
Citation 1, item 5a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$525$350Jan 27, 1995Final
Citation 1, item 5b
29 CFR 1910.1200(f)(9) · Hazard communication
Serious$0$0Jan 27, 1995Final
Citation 1, item 6a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$875$583Jan 27, 1995Final
Citation 1, item 6b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jan 27, 1995Final
Citation 1, item 6c
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Jan 27, 1995Final
Citation 1, item 6d
29 CFR 1910.107(f)(3) · Spray painting and finishing
Serious$0$0Jan 27, 1995Final
Citation 1, item 6e
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jan 27, 1995Final
Citation 1, item 6f
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jan 27, 1995Final
Citation 1, item 7a
29 CFR 1910.110(f)(7) · Storage and handling of liquefied petroleum gases
Serious$525$350Jan 27, 1995Final
Citation 1, item 7b
29 CFR 1910.110(h)(12) · Storage and handling of liquefied petroleum gases
Serious$0$0Jan 27, 1995Final
Citation 1, item 7c
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Jan 27, 1995Final
Citation 1, item 7d
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Jan 27, 1995Final
Citation 1, item 8a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$700$467Jan 27, 1995Final
Citation 1, item 8b
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jan 27, 1995Final
Citation 1, item 9
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$525$350Jan 27, 1995Final
Citation 1, item 10a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$525$350Jan 27, 1995Final
Citation 1, item 10b
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$0$0Jan 27, 1995Final
Citation 1, item 10c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jan 27, 1995Final
Citation 1, item 11
29 CFR 1910.151(b) · First aid and eyewash
Serious$525$350Jan 27, 1995Final
Citation 1, item 12a
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$525$350Jan 27, 1995Final
Citation 1, item 12b
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0Jan 27, 1995Final
Citation 1, item 13a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,225$817Jan 27, 1995Final
Citation 1, item 13b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Jan 27, 1995Final
Citation 1, item 14
29 CFR 1910.212(b) · Machine guarding
Serious$525$350Jan 27, 1995Final
Citation 1, item 15
29 CFR 1910.213(b)(6) · Woodworking machinery
Serious$700$467Jan 27, 1995Final
Citation 1, item 16
29 CFR 1910.213(f)(2) · Woodworking machinery
Serious$875$583Jan 27, 1995Final
Citation 1, item 17a
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$1,250$833Jan 27, 1995Final
Citation 1, item 17b
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$0$0Jan 27, 1995Final
Citation 1, item 17c
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 27, 1995Final
Citation 1, item 17d
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 27, 1995Final
Citation 1, item 18a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$700$467Jan 27, 1995Final
Citation 1, item 18b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Jan 27, 1995Final
Citation 1, item 18c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jan 27, 1995Final
Citation 1, item 19a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$875$583Jan 27, 1995Final
Citation 1, item 19b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 27, 1995Final
Citation 1, item 20
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$700$467Jan 27, 1995Final
Citation 1, item 21a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$525$350Jan 27, 1995Final
Citation 1, item 21b
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$0$0Jan 27, 1995Final
Citation 1, item 21c
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Jan 27, 1995Final
Citation 1, item 21d
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Jan 27, 1995Final
Citation 1, item 22a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$525$350Jan 27, 1995Final
Citation 1, item 22b
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Jan 27, 1995Final
Citation 1, item 22c
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jan 27, 1995Final
Citation 1, item 22d
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jan 27, 1995Final
Citation 1, item 23a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$525$350Jan 27, 1995Final
Citation 1, item 23b
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$0$0Jan 27, 1995Final
Citation 1, item 24
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$525$350Jan 27, 1995Final
Citation 1, item 25a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$700$467Jan 27, 1995Final
Citation 1, item 25b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jan 27, 1995Final
Citation 1, item 25c
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jan 27, 1995Final
Citation 2, item 1a
29 CFR ARM000205 A
Other-than-serious$500$333Jan 27, 1995Final
Citation 2, item 1b
29 CFR ARM000205 A
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 2
29 CFR 1910.22(b)(2) · General requirements
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 3
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 4
29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 5
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 6
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 7
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 27, 1995Final
Citation 2, item 8
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Jan 27, 1995Final

Inspection 105732465 OPENED FEB 9, 1990Closed

Complaint · No inspection · Safety · 8 employees at the site · Closed Mar 16, 1990

5325 Glen Alden Road, Sandston, VA 23231 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105732184 OPENED JUL 18, 1989Closed

Referral · Complete · Safety · 40 employees at the site · Closed Apr 23, 1990

5325 Glen Alden Road, Sandston, VA 23231 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.176(g) · Material storage and aisles
Serious$280$140Aug 17, 1989Final
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$350$175Aug 17, 1989Final
Citation 1, item 2b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Aug 17, 1989Final
Citation 1, item 2c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Aug 17, 1989Final
Citation 1, item 3a
29 CFR 1910.213(k)(1) · Woodworking machinery
Serious$350$175Aug 17, 1989Final
Citation 1, item 3b
29 CFR 1910.213(k)(2) · Woodworking machinery
Serious$0$0Aug 17, 1989Final
Citation 1, item 3c
29 CFR 1910.213(k)(3) · Woodworking machinery
Serious$0$0Aug 17, 1989Final
Citation 1, item 4
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$350$175Aug 17, 1989Final
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$350$175Aug 17, 1989Final
Citation 1, item 5b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 17, 1989Final
Citation 1, item 6a
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$350$175Aug 17, 1989Final
Citation 1, item 6b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 17, 1989Final
Citation 1, item 7
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$350$175Aug 17, 1989Final
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 2
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 3
29 CFR 1910.38(b)(1) · Emergency action plans
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 4
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 5
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 6
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 7
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 8
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 9
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 10
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 11
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
Citation 2, item 12
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 17, 1989Final
1 older inspection

Inspection 105728992 OPENED MAR 29, 1989Closed

Complaint · Complete · Health · 40 employees at the site · Closed Nov 6, 1989

5325 Glen Alden Road, Sandston, VA 23231 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$300$150Jul 26, 1989Final
Citation 1, item 1b
29 CFR 1910.22(a)(1) · General requirements
Serious$0$0Jul 26, 1989Final
Citation 1, item 2a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$180$90Jul 26, 1989Final
Citation 1, item 2b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Jul 26, 1989Final
Citation 1, item 2c
29 CFR 1910.107(e)(5) · Spray painting and finishing
Serious$0$0Jul 26, 1989Final
Citation 1, item 2d
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jul 26, 1989Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$180$90Jul 26, 1989Final
Citation 1, item 3b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Jul 26, 1989Final
Citation 1, item 3c
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jul 26, 1989Final
Citation 2, item 1a
29 CFR ARM001101 B
Other-than-serious$60$0Jul 26, 1989Final
Citation 2, item 1b
29 CFR ARM001103 A
Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 2 Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 3 Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 4
29 CFR 1910.106(e)(2)(iib) · Flammable liquids
Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 5
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 6
29 CFR 1910.134(b)(11) · Respiratory protection
Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 7
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Jul 26, 1989Final
Citation 2, item 8
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Jul 26, 1989Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Sandston site logged 7 recordable injuries or illnesses among about 231 workers: 4.4 per 100 full-time workers, against a median of 4.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ricdp
Sandston · 2025
231 704.44.6
Steves and Sons, Inc. - Ricdp
Sandston · 2024
147 1105.94.6
Richdp
Sandston · 2017
154 633.34.6

Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(e)(2)(iib)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.95 · Noise

Other wood window and door manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.