OSHA has inspected Sticks Incorporated 5 times in Iowa since 1996.
The latest one began on Jan 30, 2020 as a planned inspection, in West Des Moines.
Those inspections ended with 18 citation items: 7 serious and 11 other-than-serious.
Penalties were first proposed at $15,599 and now stand at $7,524, 52% lower after settlements or reviews.
Woodworking machinery comes up most often in these citations: 3 items under 1910.213.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Sticks Incorporated averages $4,262 (1 cited inspection).
Sticks Incorporated also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Iowa · latest 90 days of OSHA records
63employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the West Des Moines site logged 1 recordable injury or illness among about 27 workers: 4.8 per 100 full-time workers, against a median of 3.7 for its industry. Those cases cost 3 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Sticks, Inc.
West Des Moines · 2024
27
1
1
4.8
3.7
Sticks, Inc.
Des Moines · 2021
42
1
0
3.1
3.7
Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(n) Employee information and training—(1) Participation. The employer shall assure that all employees who are assigned to workplaces where there is exposure to formaldehyde participate in a training program, except that where the employer can show, using objective data, that employees are not exposed to formaldehyde at or above 0.1 ppm, the employer is not required to provide training.
(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.132 · Personal protective equipment, general requirements
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.