OSHA SearchOSHA records by employer

Stiles & Hart Brick Company: OSHA inspections and violations

Bridgewater, Massachusetts · Clay Building Material and Refractories Manufacturing · NAICS 327121

14inspections
76citation items
$26,846current penalties
Nov 1, 2024last inspection

OSHA has inspected Stiles & Hart Brick Company 14 times in Massachusetts since 1981.

The latest one began on Nov 1, 2024 after a complaint, in Bridgewater.

Those inspections ended with 76 citation items: 41 serious, 3 repeat and 32 other-than-serious.

Penalties were first proposed at $50,689 and now stand at $26,846, 47% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 18 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Stiles & Hart Brick Company averages $2,420 (1 cited inspection).

Stiles & Hart Brick Company also files yearly injury logs with OSHA, summarized below.

Stiles & Hart Brick Company: OSHA citation items per year, 1981 to 2024
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

264employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Stiles & Hart Brick Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347858656 OPENED NOV 1, 2024Closed

Complaint · Partial · Health · 10 employees at the site · Closed Apr 11, 2025

127 Cook Street Box 367, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$3,457$2,420Jan 8, 2025Final
Citation 1, item 1b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 8, 2025Final

Inspection 347730574 OPENED SEP 3, 2024Closed

Referral · Partial · Safety · 10 employees at the site · Closed Feb 17, 2025

127 Cook Street, Bridgewater, MA 02324 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339674020 OPENED APR 11, 2014Closed

Planned · Partial · Safety · 35 employees at the site · Closed Apr 23, 2014

127 Cook Street, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315144725 OPENED OCT 31, 2011Closed

Referral · Partial · Health · 35 employees at the site · Closed Oct 30, 2012

127 Cook Street, Bridgewater, MA 02324 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$4,900$2,450Feb 7, 2012Closed
Citation 1, item 1b
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Feb 7, 2012Closed
Citation 1, item 2a
29 CFR 1910.1000(c) · Air contaminants
Serious$4,900$2,450Feb 7, 2012Closed
Citation 1, item 2b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Feb 7, 2012Closed

Inspection 315144584 OPENED OCT 25, 2011Closed

Planned · Complete · Safety · 35 employees at the site · Closed Feb 13, 2012

127 Cook Street, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,975$1,488Nov 17, 2011Closed
Citation 1, item 2
29 CFR 1910.26(c)(3)(iii) · Portable metal ladders
Serious$2,975$1,488Nov 17, 2011Closed
Citation 1, item 3
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$2,975$1,488Nov 17, 2011Closed
Citation 1, item 4
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$2,975$1,488Nov 17, 2011Closed
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,517$758Nov 17, 2011Closed
Citation 1, item 6
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Nov 17, 2011Closed
Citation 2, item 1
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$700$350Nov 17, 2011Closed
Citation 2, item 2
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$700$350Nov 17, 2011Closed
Citation 2, item 3
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Nov 17, 2011Closed
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Nov 17, 2011Closed
Citation 2, item 5
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 17, 2011Closed

Inspection 310673942 OPENED AUG 14, 2007Closed

Planned · Complete · Safety · 35 employees at the site · Closed Oct 29, 2007

127 Cook Street, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,500$750Sep 25, 2007Closed
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$1,200$600Sep 25, 2007Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,200$600Sep 25, 2007Closed
Citation 1, item 4
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$1,200$600Sep 25, 2007Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,200$600Sep 25, 2007Closed
Citation 1, item 6
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,200$600Sep 25, 2007Closed

Inspection 310673959 OPENED AUG 14, 2007Closed

Planned · Complete · Health · 34 employees at the site · Closed Oct 2, 2007

127 Cook Street, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$900$450Sep 11, 2007Closed

Inspection 308102847 OPENED OCT 7, 2004Closed

Complaint · Partial · Health · 45 employees at the site · Closed May 26, 2005

127 Cook Street, Bridgewater, MA 02324 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$1,750$875Jan 5, 2005Closed
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$750$375Jan 5, 2005Closed
6 older inspections

Inspection 300337714 OPENED NOV 26, 1996Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Feb 26, 1997

127 Cook Street, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$675$300Jan 17, 1997Closed
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,125$800Jan 17, 1997Closed
Citation 2, item 1
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jan 17, 1997Closed

Inspection 109171355 OPENED MAY 18, 1995Closed

Planned · Complete · Safety · 40 employees at the site · Closed Aug 24, 1995

127 Cook Street, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$700$350Jun 7, 1995Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$875$438Jun 7, 1995Closed
Citation 1, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$700$350Jun 7, 1995Closed
Citation 1, item 4a
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$875$438Jun 7, 1995Closed
Citation 1, item 4b
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 7, 1995Closed
Citation 1, item 4c
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 7, 1995Closed
Citation 1, item 4d
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 7, 1995Closed
Citation 1, item 4e
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 7, 1995Closed
Citation 1, item 4f
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 7, 1995Closed
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$525$262Jun 7, 1995Closed
Citation 1, item 5b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jun 7, 1995Closed
Citation 1, item 5c
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$0$0Jun 7, 1995Closed
Citation 1, item 5d
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jun 7, 1995Closed
Citation 1, item 5e
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jun 7, 1995Closed
Citation 1, item 5f
29 CFR 1910.334(a)(3)(iii) · Using electrical equipment
Serious$0$0Jun 7, 1995Closed
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Jun 7, 1995Closed
Citation 2, item 2
29 CFR 1910.212(a)(2) · Machine guarding
Other-than-serious$0$0Jun 7, 1995Closed
Citation 2, item 3
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$0$0Jun 7, 1995Closed
Citation 2, item 4
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Jun 7, 1995Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 7, 1995Closed

Inspection 101146645 OPENED OCT 21, 1986Closed

Planned · Complete · Safety · 52 employees at the site · Closed Jan 16, 1987

127 Cook Street, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$600$600Nov 7, 1986Closed
Citation 1, item 1b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Repeat$0$0Nov 7, 1986Closed
Citation 1, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Repeat$120$120Nov 7, 1986Closed
Citation 2, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 2
29 CFR 1910.157(d)(1) · Portable fire extinguishers
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 3
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 5
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 6
29 CFR 1910.219(e)(5)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 7
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 8
29 CFR 1910.252(b)(4)(ixc) · Welding fire safety
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 9
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Nov 7, 1986Closed
Citation 2, item 11
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Nov 7, 1986Closed

Inspection 10144889 OPENED NOV 10, 1983Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jan 4, 1984

Cook Street, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$150$150Nov 29, 1983Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 4
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 7
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 8
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 29, 1983Closed
Citation 2, item 9
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Nov 29, 1983Closed

Inspection 10177921 OPENED JUL 14, 1981Closed

Complaint · Partial · Safety · 45 employees at the site · Closed Jun 20, 1985

Cook St, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$120$60Sep 22, 1981Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Bridgewater site logged 1 recordable injury or illness among about 29 workers: 3.2 per 100 full-time workers, against a median of 3.0 for its industry. Those cases cost 35 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Stiles and Hart Brick Company
Bridgewater · 2025
29 113.23.0

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other clay building material and refractories manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.