OSHA SearchOSHA records by employer

Strategic Armory Corps: OSHA inspections and violations

Phoenix, Arizona · Other Personal and Household Goods Repair and Maintenance · NAICS 811490

1inspections
4citation items
$600current penalties
Jul 21, 2015last inspection

OSHA has inspected Strategic Armory Corps once in Arizona.

The inspection began on Jul 21, 2015 after a complaint, in Phoenix.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $600 and still stand at $600.

Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Strategic Armory Corps averages $600 (1 cited inspection).

Strategic Armory Corps: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Strategic Armory Corps and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340789841 OPENED JUL 21, 2015Closed

Complaint · Partial · Health · 5 employees at the site · Closed Oct 14, 2015

23606 N 19th Ave Ste #10, Phoenix, AZ 85085 · Other Personal and Household Goods Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$600$600Sep 9, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Sep 9, 2015Final
Citation 1, item 1c
29 CFR 1910.107(d)(3) · Spray painting and finishing
Serious$0$0Sep 9, 2015Final
Citation 1, item 1d
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Sep 9, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(d)(3)

(3) Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.

Other other personal and household goods repair and maintenance employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.