OSHA SearchOSHA records by employer

Stratton-Taylor Builders LLC: OSHA inspections and violations

Gallatin, Tennessee · Framing Contractors · NAICS 238130

1inspections
5citation items
$1,100current penalties
Dec 7, 2016last inspection

OSHA inspectors have visited Stratton-Taylor Builders LLC in Tennessee one time.

It opened on Dec 7, 2016 as a planned inspection, in Gallatin.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $1,100 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Stratton-Taylor Builders LLC averages $1,100 across 1 cited inspection.

Stratton-Taylor Builders LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

344employers cited

20 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Stratton-Taylor Builders LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341956324 OPENED DEC 7, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Feb 1, 2017

1525 Foxland Blvd Lot #1334, Gallatin, TN 37066 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$600$600Dec 22, 2016Final
Citation 1, item 1b
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Dec 22, 2016Final
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$500$500Dec 22, 2016Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$0$0Dec 22, 2016Final
Citation 1, item 2c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Dec 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.