Sulzer Pumps (US) Inc: OSHA inspections and violations
Portland, Oregon · Pump and Compressor Manufacturing · NAICS 333911
9inspections
20citation items
$10,341current penalties
Apr 7, 2026last inspection
Sulzer Pumps (US) Inc has 9 OSHA inspections on record in Oregon, the first in 2003.
OSHA's last visit started on Apr 7, 2026 after a complaint, in Portland, and the case has not closed yet.
Across those inspections OSHA issued 20 citation items: 13 serious and 7 other-than-serious.
OSHA proposed $11,891 in penalties. After settlements and reviews the total is $10,341, down 13%.
Most often, OSHA cited 1910.134, respiratory protection (7 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Sulzer Pumps (US) Inc averages $2,729 over 3 cited inspections in that time.
Sulzer Pumps (US) Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Oregon · latest 90 days of OSHA records
391employers cited
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Portland site logged 11 recordable injuries or illnesses among about 338 workers: 3.1 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 25 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Sulzer Pumps
Portland · 2019
338
11
2
3.1
1.9
Included with any plan: 1 more yearly log from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(1) General requirements. (i) The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.