OSHA SearchOSHA records by employer

Summit Trailers, LLC.: OSHA inspections and violations

Schuylkill Haven, Pennsylvania · Truck Trailer Manufacturing · NAICS 336212

1inspections
10citation items
$34,150current penalties
Feb 19, 2026last inspection

Summit Trailers, LLC. has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Feb 19, 2026 as a planned inspection, in Schuylkill Haven, and the case has not closed yet.

From that inspection OSHA issued 10 citation items: 10 serious.

OSHA proposed $56,933 in penalties. After settlements and reviews the total is $34,150, down 40%.

Most often, OSHA cited 1910.212, machine guarding (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Summit Trailers, LLC. averages $34,150 over 1 cited inspection in that time.

Summit Trailers, LLC. also files yearly injury logs with OSHA, summarized below.

Summit Trailers, LLC.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Summit Trailers, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348761859 OPENED FEB 19, 2026Open

Planned · Complete · Safety · 27 employees at the site · Open

2174 Fair Road, Schuylkill Haven, PA 17972 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$9,268$5,564Jul 8, 2026Final
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$9,268$5,564Jul 8, 2026Final
Citation 1, item 3
29 CFR 1910.36(e)(2) · Exit route design
Serious$5,296$3,165Jul 8, 2026Final
Citation 1, item 4
29 CFR 1910.37(a)(2) · Exit routes
Serious$5,296$3,165Jul 8, 2026Final
Citation 1, item 5
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$5,296$3,165Jul 8, 2026Final
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,972$2,387Jul 8, 2026Final
Citation 1, item 7
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,621$3,976Jul 8, 2026Final
Citation 1, item 8
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$3,972$2,388Jul 8, 2026Final
Citation 1, item 9
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$3,972$2,388Jul 8, 2026Final
Citation 1, item 10
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$3,972$2,388Jul 8, 2026Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Schuylkill Haven site logged 7 recordable injuries or illnesses among about 30 workers: 26.4 per 100 full-time workers, against a median of 5.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Summit Trailers LLC
Schuylkill Haven · 2025
30 7026.45.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.184 · Slings

29 CFR 1910.184(e)(4)

(4) Proof testing. The employer shall ensure that before use, each new, repaired, or reconditioned alloy steel chain sling, including all welded components in the sling assembly, shall be proof tested by the sling manufacturer or equivalent entity, in accordance with paragraph 5.2 of the American Society of Testing and Materials Specification A391-65, which is incorporated by reference as specified in § 1910.6 (ANSI G61.1-1968). The employer shall retain a certificate of the proof test and shall make it available for examination.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other truck trailer manufacturing employers in Pennsylvania