OSHA SearchOSHA records by employer

Sun Belle Inc.: OSHA inspections and violations

Jessup, Maryland · Other Grocery and Related Products Merchant Wholesalers · NAICS 424490

1inspections
3citation items
$562current penalties
Nov 30, 2016last inspection

Sun Belle Inc. has one OSHA inspection on record in Maryland.

OSHA opened it on Nov 30, 2016 as a planned inspection, in Jessup.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $562 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,425. Sun Belle Inc. averages $562 over 1 cited inspection in that time.

Sun Belle Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

197employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Sun Belle Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341940476 OPENED NOV 30, 2016Closed

Planned · Complete · Safety · 55 employees at the site · Closed Apr 21, 2017

8375 Patuxent Range Rd., Jessup, MD 20794 · Other Grocery and Related Products Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$562$562Feb 21, 2017Final
Citation 1, item 1b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Feb 21, 2017Final
Citation 2, item 1
29 CFR 1910.37(b)(5) · Exit routes
Other-than-serious$0$0Feb 21, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(b)(5)

(5) Each doorway or passage along an exit access that could be mistaken for an exit must be marked “Not an Exit” or similar designation, or be identified by a sign indicating its actual use (e.g., closet).

Other other grocery and related products merchant wholesalers employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.